27
Service Facts
M952-SF-4
Fault LED Flash Codes Definitions
INTEGRATED FURNACE CONTROL LED FLASH CODES
RED LED - LitePort
TM
DATA - 1 FLASH EVERY 20 SECONDS
2 Flashes ---
RETRIES OR RECYCLES EXCEEDED
3 Flashes ---
INDUCER OR PRESSURE SWITCH ERROR
4 Flashes ---
OPEN LIMIT OR ROLLOUT SWITCH
5 Flashes ---
FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT
6 Flashes ---
LINE REVERSE POLARITY
7 Flashes ---
GAS VALVE CIRCUIT ERROR
8 Flashes ---
WEAK FLAME
9 Flashes ---
OPEN INDUCER LIMIT ERROR
GREEN LED - STATUS
Slow Flash
NORMAL, NO CALL FOR HEAT
Fast Flash
NORMAL, CALL FOR HEAT PRESENT
GREEN and RED
LED's on Continuously FUSE OPEN OR INTERNAL CONTROL FAILURE
Summary of Contents for M952V060BD36AB
Page 7: ...7 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345191P01...
Page 8: ...8 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM2 From drawing D345191P01...
Page 9: ...9 Service Facts M952 SF 4 M952 WIRING DIAGRAM From drawing D345192...
Page 10: ...10 Service Facts M952 SF 4 M952 SCHEMATIC DIAGRAM From drawing D345192...
Page 37: ...37 Service Facts M952 SF 4...