18
FROM STARTER FAULT CHART
NO CHECK FOR PHASE MONITOR OR ANY OTHER SHUTDOWN WIRED TO BTS1-33 & 29
ORIGINAL INTELLISYS CONTROLLER
MEASURE VOLTAGE AC
TERMINAL BTS1-33 AND BTS1-3
IS THE VOLTAGE GREATER THAN
110 VAC?
NO. BAD CONTACT ON E-STOP
YES. MEASURE VOLTAGE AC
TERMINAL BTS1-31 AND BTS1-3
IS THE VOLTAGE GREATER THAN
110 VAC?
NO. BAD 1ATS
YES. MEASURE VOLTAGE AC
TERMINAL BTS1-29 AND BTS1-3
DOES VOLTAGE CONTINUOUSLY
READ 110-130 VAC AT TIME OF
SHUTDOWN?
YES. CHECK FOR BAD CONTROLLER OR RIBBON CABLE. RECHECK STARTER
SEQUENCE.