4
SERVICING THE TOOL
Lubrication
Ingersoll--Rand No. 50
Ingersoll--Rand No. 100
Always use an air line lubricator with these tools.
We recommend the following Filter--Regulator--Lubricator
(FRL) Unit:
For USA use Unit Number C28--04--FKG0--28
After each eight hours of operation,
unless an air line
lubricator is used, inject 1.5 cc of Ingersoll--Rand
No. 50 Oil into the inlet of the tool and run the tool
briefly.
After each forty--eight hours of operation,
or as
experience indicates, inject about 3 cc of Ingersoll--Rand
No. 100 Grease into the Grease Fitting (11).
(Dwg. TPD905--2)
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool’s Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut--Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool’s Inlet Ø
SPECIFICATIONS
Model
Type of
Handle
Drive
Impacts
per min.
Recommended
Torque Range
H
Sound Level
dB (A)
♦
Vibrations
Level
in.
ft--lbs (Nm)
Pressure
•
Power
m/s
2
IR--C212
pistol
3/8” sq. dr.,
ring--type
retainer
1500
20--125 (27--170)
97.5
110.5
2.7