OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE
STATIC SPARK

 

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause person-

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the
pump model plate.

S

Be sure material hoses and other components are able to with-
stand fluid pressures developed by this pump. Check all hoses
for damage or wear. Be certain dispensing device is clean and
in proper working condition.

WARNING

 

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

S

Use the pump grounding screw terminal provided. Use ARO

R

part no. 66885-1 ground kit or connect a suitable ground wire
(12 ga. min.) to a good earth ground source.

S

Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific
grounding requirements.

S

After grounding, periodically verify continuity of electrical path
to ground. Test with an ohmmeter from each component (e.g.,
hoses, pump, clamps, container, spray gun, etc.) to ground to
insure continuity. Ohmmeter should show 0.1 ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid free streaming
of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

WARNING

 

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and per-
sonnel.

S

In the event of a diaphragm rupture material can be forced out
of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping haz-
ardous or inflammable materials.

S

Use a grounded 1" minimum i.d. hose between the pump and
the muffler.

WARNING

 

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sys-
tem by opening dispensing valve or device and / or carefully
and slowly loosening and removing outlet hose or piping from
pump.

WARNING

 

HAZARDOUS MATERIALS. Can cause serious

injury or property damage. Do not attempt to return a pump to
the factory or service center that contains hazardous material.
Safe handling practices must comply with local and national
laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.

WARNING

 

EXPLOSION HAZARD. Models containing alumi-

num wetted parts cannot be used with 1,1,1-trichloroethane,
methylene chloride or other halogenated hydrocarbon sol-
vents which may react and explode.

S

Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using with solvents
of this type.

WARNING

 

MISAPPLICATION HAZARD. Do not use models

containing aluminum wetted parts with food products for hu-
man consumption. Plated parts can contain trace amounts of
lead.

CAUTION

 

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or re-
circulated. Chemical compatibility may change with tempera-
ture and concentration of the chemical(s) within the
substances being pumped, flushed or circulated. For specific
fluid compatibility, consult the chemical manufacturer.

CAUTION

 

Maximum temperatures are based on mechani-

cal stress only. Certain chemicals will significantly reduce
maximum safe operating temperature. Consult the chemical
manufacturer for chemical compatibility and temperature lim-
its. Refer to PUMP DATA on page 1 of this manual.

CAUTION

 

Be certain all operators of this equipment have

been trained for safe working practices, understand it’s limita-
tions, and wear safety goggles / equipment when required.

CAUTION

 

Do not use the pump for the structural support of

the piping system. Be certain the system components are
properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible connec-
tions (such as hose), not rigid piped, and should be compatible
with the substance being pumped.

CAUTION

 

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periods
of time.

S

Disconnect air line from pump when system sits idle for long
periods of time.

CAUTION

 

Use only genuine ARO replacement parts to as-

sure compatible pressure rating and longest service life.

WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or
substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product or
property damage.

= Important installation, operation or 

maintenance information.

Summary of Contents for ARO PD30 C Series

Page 1: ...to 66_ C Nitrile 10_ to 180_ F 12_ to 82_ C KynarR PVDF 10_ to 200_ F 12_ to 93_ C SantopreneR 40_ to 225_ F 40_ to 107_ C TeflonR P T F E 40_ to 225_ F 4_ to 107_ C VitonR 40_ to 350_ F 40_ to 177_ C Dimensional Data see page 8 Mounting Dimensions 10 5 32 x 12 1 16 258 mm x 306 mm Noise Level 70 p s i 50 c p m À 83 0 db A Á À Tested with 67263 muffler assembly installed Á The pump sound pressure ...

Page 2: ...ATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alumi n...

Page 3: ...S Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time S Service kits are divided to service two separate diaphragm pump functions 1 AIR SECTION 2 FLUID SECTION The FLUID SEC TION is divided further to match typical part MATERIAL OPTIONS S Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and f...

Page 4: ...r 2 94831 1 C 94831 1 C 94831 2 SS 94831 2 SS 68 Air Cap 1 94030 1 A 94721 1 A 94031 1 SS 94031 1 SS 69 Air Cap 1 94030 2 A 94721 2 A 94031 2 SS 94031 2 SS 76 Pipe Plug 1 8 27 N P T x 0 27 1 Y17 50 S SS Y17 50 S SS 126 Pipe Plug 1 4 18 N P T x 7 16 2 Y17 51 S SS Y17 51 S SS Y17 51 S SS 131 Screw M10 x 1 5 6g x 120 mm 4 94531 C 94531 C 96656 SS 96656 SS Ln 175 O Ring 3 32 x 1 o d 2 Y325 117 B Y325 ...

Page 5: ...ly Loctite 271 to threads G Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using Stainless steel fasteners NOT USED WITH PX30X XXX AXX C CXX C GXX C Z Lubriplate FML 2 is a white food grade petroleum grease MSDS available upon request COLOR CODE DIAPHRAGM BALL MATERIAL COLOR COLOR Hytrel Cream Cream Nitrile Black Red S Santoprene Tan Tan Santoprene ...

Page 6: ...XX C only Items not shown K Fluid Section Kit parts see page 4 AIR MOTOR SECTION SERVICE Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERAL REASSEMBLY NOTES S Air Motor Section Service is continued from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on metallic surfaces and nicks or cuts in O rings S Take precautions to p...

Page 7: ...able separately which includes the following 637374 2 for models PD30A X X C 105 4 111 128 2 132 133 3 134 135 136 137 138 139 140 141 166 176 2 199 200 233 240 2 241 242 243 and 244 637374 4 for models PD30S X X C 105 4 111 128 2 132 133 3 134 135 136 137 138 139 140 141 146 147 2 176 2 199 200 233 240 2 241 242 243 and 244 637374 3 for models PE30A X X C 76 105 4 111 128 2 132 133 3 134 135 136 ...

Page 8: ...ng type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspect the pump for solid objects lodged in the diaphragm chamber or the seat area DIMENSIONAL DATA Dimensions shown are for reference only they are displayed in inches and millimeters mm PX30X AXX XXX C 3 8 N P T F 1 PX30X BXX XXX C Rp 3 3 11 BSP parallel Air Inlet...

Reviews: