background image

Page 2 of 8 

PD20E-X-X (en)

EXCESSIVE AIR PRESSURE
S TATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause per- 

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fluid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.

WARNING

 

STATIC SPARK. Can cause explosion resulting in 

severe injury or death. Ground pump and pumping system. 
Sparks can ignite fl ammable material and vapors.  
The pumping system and object being sprayed must be 
grounded when it is pumping, fl ushing, recirculating or 
spraying fl ammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding 
atmosphere is conducive to spontaneous combustion. 
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and 
sparks.
Keep containers closed when not in use.

WARNING

 

Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 1” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 

HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 
or clean pump, hoses or dispensing valve while the 
system is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 

HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must comply 
with local and national laws and safety code requirements.

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 

EXPLOSION HAZARD. Models containing 

aluminum wetted par ts cannot be used with 
1,1,1-trichloroethane, methylene chloride or other 
halogenated hydrocarbon solvents which may react 
and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

WARNING

 

MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 
products for human consumption. Plated parts can 
contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based 

on mechanical stress only. Certain chemicals will 
significantly reduce maximum safe operating 
temperature. Consult the chemical manufacturer for 
chemical compatibility and temperature limits. Refer 
to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, 
understand it’s limitations, and wear safety goggles / 
equipment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 
components are properly supported to prevent stress 
on the pump parts.
Suction and discharge connections should be fl exible 
connections (such as hose), not rigid piped, and should 
be compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 
material for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.

CAUTION

 

Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

  R E -TO R Q U E   A L L   FA S T E N E R S   B E F O R E 

OPERATION. Creep of housing and gasket materials may 
cause fasteners to loosen. Re-torque all fasteners to insure 
against fl uid or air leakage.

WARNING

=

Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.

CAUTION

=

Hazards or unsafe practices which 
could result in minor personal injury, 
product or property damage.

NOTICE

=

Important installation, operation or
maintenance information.

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Summary of Contents for ARO PD20E Series

Page 1: ...aphragm ball seal material E P R EPDM 600 to 2800 F 510 to 1380 C Hytrel 200 to 1500 F 29 to 660 C Nitrile 100 to 1800 F 12 to 820 C Polypropylene 350 to 1750 F 20 to 790 C Santoprene 400 to 2250 F 40...

Page 2: ...service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y y y y y y y y y y y y y y y Obtain Material Safety Da...

Page 3: ...d grounded Flooded suction inlet pressure must not exceed 10 p s i g 0 69 bar y y y y y y y y y y y y OPERATING INSTRUCTIONS Always flush the pump with a solvent compatible with the material being pum...

Page 4: ...50 4 V MATERIAL CODE B Nitrile C Carbon Steel Co Copper E E P R GP Groundable Polypropylene H Hytrel P Polypropylene SP Santoprene SS Stainless Steel T PTFE V Viton COMMON PARTS Item Description size...

Page 5: ...ze compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners NOTE Lubriplate FML 2 is a white food grade petroleum grease COLOR CODE DIAPHRAGM BALL...

Page 6: ...Major Valve GENERAL REASSEMBLY NOTES Air Motor Section Service is continued from Fluid Section repair Inspect and replace old parts with new parts as necessary Look for deep scratches on surfaces and...

Page 7: ...mating parts 136 137 139 111 138 105 135 133 134 101 103 174 121 118 173 169 172 171 170 167 173 121 174 118 166 132 147 146 199 141 200 232 232 233 176 PILOT VALVE PART GROUP MAJOR VALVE A 637374 6...

Page 8: ...ld be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collaps ing type capable of pulling a high v...

Reviews: