GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 
at low air pressure and a broad range of material compatibility 
options available. Refer to the model and option chart. ARO 
pumps feature stall resistant design, modular air motor / fl uid 
sections. 
Air operated double diaphragm pumps utilize a pressure dif-
ferential in the air chambers to alternately create suction and 
positive fl uid pressure in the fl uid chambers, ball checks insure 
a positive fl ow of fl uid. 
Pump cycling will begin as air pressure is applied and it will 
continue to pump and keep up with the demand. It will build 
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and 
will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 
microns should be used on the air supply. There is no lu-
brication required other than the “O” ring lubricant which is 
applied during assembly or repair.
If lubricated air is present, make sure that it is compatible 
with the “O” rings and seals in the air motor section of 
the pump.

y

y

 Viton

®

and Hytrel

®

 are registered trademarks of the DuPont

®

  Company  Loctite

®

 is a registered trademark of Henkel Loctite Corporation 

  Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.  Lubriplate

®

 is a registered trademark of Lubriplate Division (Fiske Brothers Refi ning Company)   

OPERATING INSTRUCTIONS

Always flush the pump with a solvent compatible with 

y

MAINTENANCE

Certain ARO “Smart Parts” are indicated which should be 
available for fast repair and reduction of down time.
Provide a clean work surface to protect sensitive internal 
moving parts from contamination from dirt and foreign 
matter during service disassembly and reassembly.
Keep good records of service activity and include pump 
in preventive maintenance program.
Service Kits are available to service two separate Dia-
phragm Pump functions: 1. AIR SECTION, 2. FLUID SEC-
TION. The Fluid Section is divided further to match typical 
active MATERIAL OPTIONS.

y

y

y

y

the material being pumped if the material being pumped 
is subject to “setting up” when not in use for a period of 
time.
Disconnect the air supply from the pump if it is to be in-
active for a few hours.
The outlet material volume is governed not only by the 
air supply but also by the material supply available at the 
inlet. The material supply tubing should not be too small 
or restrictive. Be sure not to use hose which might col-
lapse.
When the diaphragm pump is used in a forced-feed 
(fl ooded inlet) situation, it is recommended that a Check 
Valve” be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to 
insure against damage by vibration.

y

y

y

y

TYPICAL CROSS SECTION

Figure 2

Summary of Contents for ARO PD03P Series

Page 1: ...100 to 2000 F 12 to 930 C Neoprene 00 to 2000 F 18 to 930 C Nitrile 100 to 1800 F 12 to 820 C Polypropylene 350 to 1750 F 20 to 790 C Santoprene 400 to 2250 F 400 to 1070 C PTFE 400 to 2250 F 40 to 1...

Page 2: ...o not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y y y y...

Page 3: ...Corporation Santoprene is a registered trademark of Monsanto Company licensed to Advanced Elastomer Systems L P Lubriplate is a registered trademark of Lubriplate Division Fiske Brothers Refining Com...

Page 4: ...Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl 6 Diaphragm Nut 1 4 20 2 93810 7 P 93810 7 P 93810 3 K 93810 3 K 93810 2 D 93810 2 D 15 Fluid Cap 2 96460 1 P 96460 1 P 96460 3...

Page 5: ...s Apply Loctite 242 to threads Apply Lubriplate 94276 to all O rings U cups and mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stain...

Page 6: ...cket or wrench 5 16 Allen wrench T 10 Torx screwdriver torque wrench measuring inch pounds O ring pick y y y FLUID SECTION DISASSEMBLY Remove 61 top manifold Remove 19 O rings 21 seats and 22 balls Re...

Page 7: ...111 spool LIPS MUST FACE EACH OTHER Assemble 137 O rings to 136 large plug Assemble 137 and 166 O rings to 107 small plug Insert 111 spool into 136 large plug then insert 136 large plug into 135 valv...

Page 8: ...pe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be non collapsible type capable of pulling a h...

Page 9: ...PD03P XXX XXX en Page 9 of 12 ACCESSORIES Figure 6 67388 WALL MOUNT BRACKET ASSEMBLY 96507 Wall Mount Bracket Y13 3 T Washer 3 3 16 Y14 10 S Lock Washer 3 10 Y154 52 S Cap Screw 3 10 24 x 1 2...

Page 10: ...Page 10 of 12 PD03P XXX XXX en...

Page 11: ...PD03P XXX XXX en Page 11 of 12...

Page 12: ...Page 12 of 12 PD03P XXX XXX en PN 97999 1180...

Reviews: