66620XĆXĆC
Page 8 of 8
TROUBLE SHOOTING
Product discharged from exhaust outlet.
S
Check for diaphragm rupture.
S
Check tightness of diaphragm nut.
Air bubbles in product discharge.
S
Check connections of suction plumbing.
S
Check O" rings between intake manifold and fluid caps.
S
Check tightness of diaphragm nut.
Low output volume, erratic flow or no flow.
S
Check air supply.
S
Check for plugged outlet hose.
S
Check for kinked (restrictive) outlet material hose.
S
Check for kinked (restrictive) or collapsed inlet material hose.
S
Check for pump cavitation Ć suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a nonĆcolĆ
lapsing type, capable of pulling a high vacuum.
S
Check all joints on the inlet manifolds and suction connections.
These must be air tight.
S
Inspect the pump for solid objects logged in the diaphragm chamber
or the seat area.
DIMENSIONAL DATA
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
11Ć1/2"
(292 mm)
19Ć7/8"
(505 mm)
18Ć3/8"
(467 mm)
13Ć1/8"
(333 mm)
11Ć3/4"
(298 mm)
2Ć3/4"
(70 mm)
9"
(229 mm)
1/2" Slot
(14 mm)
2 Ć 11Ć1/2 N.P.T.F. Ć 1
(models 66620XĆXXXĆC and 66621XĆXXXĆC)
Rp 2 (2 Ć 11 B.S.P.
parallel) (models 66622XĆXXXĆC and 66623XĆXXXĆC)
7Ć5/8"
(194 mm)
12Ć3/4"
(324 mm)
Air Inlet 1/2 Ć 14 N.P.T.
Air Exhaust Thread
3/4 Ć 14 N.P.T.
Outlet
Inlet
Figure 4
PN 97999Ć32