background image

66620XĆXĆC

Page  8 of 8

TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of diaphragm nut.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check O" rings between intake manifold and fluid caps.

S

Check tightness of diaphragm nut.

Low output volume, erratic flow or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation Ć suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a nonĆcolĆ
lapsing type, capable of pulling a high vacuum.

S

Check  all  joints  on  the  inlet  manifolds  and  suction  connections.
These must be air tight.

S

Inspect the pump for solid objects logged in the diaphragm chamber
or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

11Ć1/2" 

(292 mm)

19Ć7/8"

(505 mm)

18Ć3/8"

(467 mm)

13Ć1/8" 

(333 mm)

11Ć3/4"

 (298 mm)

2Ć3/4"

(70 mm)

9"

 (229 mm)

1/2" Slot 

(14 mm)

2 Ć 11Ć1/2 N.P.T.F. Ć 1 

(models 66620XĆXXXĆC and 66621XĆXXXĆC)

Rp 2 (2 Ć 11 B.S.P. 

parallel) (models 66622XĆXXXĆC and 66623XĆXXXĆC)

7Ć5/8"

(194 mm)

12Ć3/4"

 (324 mm)

Air Inlet 1/2 Ć 14 N.P.T.

Air Exhaust Thread
3/4 Ć 14 N.P.T.

Outlet

Inlet

Figure 4

PN 97999Ć32

Summary of Contents for ARO 66620 C Series

Page 1: ...rethane 10_ to 150_ F 12_ to 66_ C P V D F KynarR 10_ to 200_ F 12_ to 93_ C SantopreneR 40_ to 225_ F 40_ to 107_ C 0_ to 225_ F 4_ to 107_ C VitonR 40_ to 350_ F 40_ to 177_ C Dimensional Data see p...

Page 2: ...e while the system is pressurized S Disconnect air supply line and relieve pressure from the sys tem by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hos...

Page 3: ...uitable surface to insure against damage by vibration MAINTENANCE Refer to the part views and descriptions as provided on pages 4 through 7 for parts identification and service kit information S Certa...

Page 4: ...4 o d Qty Mtl XX1 637124 X1 92755 1 2 N Y325 16 4 B Y325 230 4 B XX2 637124 X2 2 B Y325 16 4 B Y325 230 4 B XX3 637124 X3 92755 3 2 V Y328 16 4 T Y327 230 4 V XX4 637124 X4 94617 94616 2 T SP Y328 16...

Page 5: ...ENE Green Green S NITRILE Black Red S SANTOPRENE Tan Tan SANTOPRENE Green N A Backup White White URETHANE N A Red VITON Yellow Yellow S Stripe S Dot See item 8 in inset below 21 19 k 22 26 16 59 15 22...

Page 6: ...AL REASSEMBLY NOTES S Air Motor Section Service is continued from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on metallic surfaces and nick...

Page 7: ...S SECTION DETAIL 109 110 k 112 114 k 113 k 115 111 116 Figure 3 107 127 126Z LUBRICATION SEALANTS IMPORTANT BE CERTAIN TO ORIENT 115 SPACER LEGS AWAY FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING AIR...

Page 8: ...the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the i...

Reviews: