651412-X MATERIAL FILTER

Maximum Working Pressure 5,000 P.S.I. (345 Bar)

 

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

 

 OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Use only genuine ARO® replacement parts to assure compat-
ible pressure rating and longest service life.

INSTALLATION

Identify the regulator INLET / OUTLET (flow direction). The 
regulator is marked with an arrow on the body base. Refer to 
the (6) body (fi gure 2, page 4).

OPERATING AND SAFETY PRECAUTIONS

Read and heed all warnings, cautions and safety precau-
tions before operation of this unit.

CAUTION

 Be certain all operators of this equipment have 

been trained for safe working practices, understand it’s 
limitations, and wear safety goggles / equipment when re-
quired.

WARNING

 EXCESSIVE FLUID PRESSURE. Can cause pump 

damage, personal injury or property damage.
Do not exceed the maximum inlet air pressure as stated on 
the pump model plate.
Be sure material hoses and other components are able to 
withstand fl uid pressures developed by this pump. Check 
all hoses for damage or wear. Be certain dispensing device 
is clean and in proper working condition.

WARNING

 INJECTION HAZARD. Any material injected into 

flesh can cause severe injury or death. If an injection oc-
curs, immediately contact a doctor.
Do not grab front end of dispensing device.
Do not aim dispensing device at anyone or any part of the 
body.
Disconnect air supply line and relieve pressure from the 
system by opening dispensing valve or device and / or 
carefully and slowly loosening and removing outlet hose or 
piping from pump.

WARNING

 MISAPPLICATION HAZARD. Do not use the fi lter 

when the fluid inlet pressure is too high for the designed 
operating range. Excessive  inlet pressure can cause failure.

WARNING

 HAZARDOUS PRESSURE. Can result in serious 

injury or property damage. Do not service or clean pump, 
hoses or dispensing valve while the system is pressurized.

WARNING

 HAZARDOUS MATERIALS. Can cause serious in-

jury or property damage. Do not attempt to return a pump 
to the factory or service center that contains hazardous 
material. Safe handling practices must comply with local 
and national laws and safety code requirements.

y

y

y

y

y

y

y

y

WARNING

 DISASSEMBLY HAZARD. Do not disassemble 

the fi lter when it is under pressure. Relieve pressure in the 
pumping system before attempting service or disassembly 
procedures. Disconnect air lines and carefully bleed pres-
sure off  the system. Be certain the system is not maintain-
ing pressure due to a material restriction in the hose, line, 
dispensing device, or the spray or extrusion tip. Failure to 
relieve pressure, both upstream and downstream, may re-
sult in an injury upon disassembly.

WARNING

 PREVENT FIRES. Keep solvents away from heat, 

sparks, or open fl ame. Keep containers closed when not in 
use. When pumping, flushing or recirculating volatile sol-
vents, be certain the area is adequately ventilated.

WARNING

  =  Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  =  Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  =  Important installation, operation or 

maintenance information.

 

Figure 1

Summary of Contents for ARO 651412-X

Page 1: ...t aim dispensing device at anyone or any part of the body Disconnect air supply line and relieve pressure from the system by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hose or piping from pump WARNING MISAPPLICATION HAZARD Do not use the filter when the fluid inlet pressure is too high for the designed operating range Excessive inlet pressure can c...

Page 2: ... buenas condiciones de funciona miento Desconecte la línea de alimentación de aire y alivie la presión del sistema abriendo la válvula o el dispositivo de despacho y o quitando la manguera de salida o la tubería de la bomba aflojándolas lenta y cuidadosamente ADVERTENCIA PELIGRO POR USO INDEBIDO Cuando la presión a la entrada del fluido es demasiado alta para el margen nominal de funcionamiento no...

Page 3: ...le clapet ou dispositif de débit et ou en desserrant lentement et avec précaution le tuyau de sortie ou la canalisation pour l enlever de la pompe MISEENGARDE DANGER RELATIF À UNE MAUVAISE UTILI SATION Ne pas utiliser le filtre lorsque la pression d entrée de liquide est trop élevée pour la gamme de pression d utilisation prévue Une pression d entrée excessive peut provoquer une défaillance MISEEN...

Page 4: ...3 6 Body 1 91453 7 Tube and Cap Assembly 1 65979 8 Ball 0 5000 o d 1 Y16 116 9 Pipe Plug 1 4 18 N P T 3 Y17 51 N c ApplyTeflon tape to threads Aplique cinta deTeflón a las roscas Mettre du rubanTéflon sur les filets y ARO is a registered trademark of Ingersoll Rand Company y y ARO es una marca registrada Ingersoll Rand Company y y ARO est une marque déposée de Ingersoll Rand Company y PARTS LIST L...