Ingersoll-Rand ARO 650715-C Operator'S Manual Download Page 3

66610X-X-C (en) 

Page 3 of 12

EXCESSIVE AIR PRESSURE 

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

 EXCESSIVE AIR PRESSURE. Can cause 

personal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as stated 

on the pump model plate.

 

y

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

  STATIC SPARK. Can cause explosion 

resulting in severe injury or death. Ground pump and 

pumping system.

 

y

Sparks can ignite flammable material and vapors.

 

y

The pumping system and object being sprayed must 

be grounded when it is pumping, flushing, recirculat-

ing or spraying flammable materials such as paints, 

solvents, lacquers, etc. or used in a location where 

surrounding atmosphere is conducive to spontaneous 

combustion. Ground the dispensing valve or device, 

containers, hoses and any object to which material is 

being pumped.

 

y

Use the pump grounding screw terminal provided. 

Use ARO part no. 66885-1 ground kit or connect a 

suitable ground wire (12 ga. minimum) to a good 

earth ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of elec-

trical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use

 

y

WARNING

 Pump exhaust may contain contam-

inants. Can cause severe injury. Pipe exhaust away 

from work are and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 3/8” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 

or clean pump, hoses or dispensing valve while the 

system is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING  

HAZARDOUS MATERIALS. Can cause 

serious injury or property damage. Do not attempt 

to return a pump to the factory or service center that 

contains hazardous material. Safe handling practices 

must comply with local and national laws and safety 

code requirements.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions. 

 

y

WARNING  

EXPLOSION HAZARD. Models con-

taining aluminum wetted parts cannot be used with 

1,1,1-trichloroethane, methylene chloride or other 

halogenated hydrocarbon solvents which may react 

and explode

.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

CAUTION  

Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION  

Maximum temperatures are based 

on mechanical stress only. Certain chemicals will 

significantly reduce maximum safe operating 

temperature. Consult the chemical manufacturer for 

chemical compatibility and temperature limits. Refer 

to PUMP DATA on page 1 of this manual.

CAUTION  

Be certain all operators of this equipment 

have been trained for safe working practices, 

understand it’s limitations, and wear safety goggles / 

equipment when required.

CAUTION  

Do not use the pump for the structural 

support of the piping system. Be certain the system 

components are properly supported to prevent stress 

on the pump parts.

 

y

Suction and discharge connections should be flexible 

connections (such as hose), not rigid piped, and should 

be compatible with the substance being pumped.

CAUTION  

Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 

material for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION  

Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

 

Replacement warning labels are 

available upon request: “Static Spark” (93616-1) and 

“Diaphragm Rupture” (93122).

WARNING

Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

Hazards or unsafe practices which 

could result in minor personal inju-

ry, product or property damage.

NOTICE

Important installation, operation or

maintenance information.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

RELEASED 13/Nov/2018 12:24:02 GMT

Summary of Contents for ARO 650715-C

Page 1: ...r Maximum Material Inlet Pressure 10 psig 0 69 bar Maximum Outlet Pressure 120 psig 8 3 bar Maximum Flow Rate flooded inlet 35 gpm 133 lpm Displacement Cycle 100 psig Standard Diaphragm 0 16 gal 0 60...

Page 2: ...4 PVDF 2 316 Stainless Steel 3 Polypropylene BALL MATERIAL 8 Hard 440 Stainless Steel 0 Aluminum Single A Aluminum Single Steel Hardware Stainless Steel Hardware 1 Stainless Steel Single B Stainless S...

Page 3: ...ensing valve or device and or carefully and slowly loosening and removing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to ret...

Page 4: ...d foreign matter during service disassembly and reassembly y y Keep good records of service activity and include pump in preventive maintenance program y y Before disassembling empty captured material...

Page 5: ...T XX9 637119 XX9 C 637119 X9 C 90533 9 2 H Y328 14 4 T Y327 126 4 V XXB 637119 XXB C 637119 XB C 90533 B 2 SP Y328 14 4 T 90534 4 E MANIFOLD FLUID CAP MATERIAL OPTIONS 6661XX XXX C Aluminum 6661X0 X...

Page 6: ...ow Stripe Dot See item 8 in inset below TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS 14 Bolt 25 30 ft lbs 33 9 40 7 Nm 26 Bolts and 29 nuts 120 140 in lbs 13 6 15 8 Nm 105 40 50 in lbs 4 5 5...

Page 7: ...to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners 7 8 View for X44 PTFE diaphragm configuration only AIR SIDE SANTOPRENE GREEN when used as backer...

Page 8: ...l force the 109 piston out Continue pushing the 111 spool and remove Check for scratches and gouges 3 Reach into the air section exhaust side and remove 116 spacer 115 spacers 113 O rings 114 O rings...

Page 9: ...NT 115 SPACER LEGS AWAY FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING AIR SECTION MAJOR VALVE CROSS SECTION DETAIL 109 110 112 114 113 115 111 116 Figure 4 Figure 5 124 LUBRICATION SEALANTS Apply Key...

Page 10: ...O rings between intake manifold and fluid caps y y Check tightness of diaphragm nut Low output volume erratic flow or no flow y y Check air supply y y Check for plugged outlet hose y y Check for kink...

Page 11: ...11 BSP 66612X 66613X 1 11 1 2 NPTF 1 66610X 66611X 1 11 BSP 66612X 66613X DIMENSIONAL DATA 6661X1 6661XB Dimensions shown are for reference only they are displayed in inches and millimeters mm Figure...

Page 12: ...Page 12 of 12 66610X X C PN 97999 100 RELEASED 13 Nov 2018 12 24 02 GMT...

Reviews: