![Ingersoll-Rand 7811G Product Information Download Page 3](http://html1.mh-extra.com/html/ingersoll-rand/7811g/7811g_product-information_2059514003.webp)
04579629_ed4
EN-1
EN
Product Safety Information
Intended Use:
These Air Drills are designed for drilling, honing, reaming and hole sawing.
For additional information refer to Product Safety Information Manual Form 04580353.
Manuals can be downloaded from iredge.com.
Product Specifications
Model
Chuck Size
Free Speed
Rated Power
Tool Weight
Overall Length
in
mm
rpm
hp
kW
lbs
Kg
in
mm
7811G
3/8
10
1700
0.5
0.38
2.7
1.22
7.4
188
EC112
1/2
13
500
0.5
0.38
3.67
1.67
7.9
200
Model
Average Air
Consumption
Air Consumption
@ Load
Sound Level dB(A)
(ISO15744)
Vibration (m/s²)
(ISO28927)
cfm
l/min
cfm
l/min
† Pressure (L
p
) ‡ Power (L
w
)
7811G
4
113
29
825
87.1
98.1
<2.5
EC112
4
113
27
765
86.2
97.2
<2.5
† K
pA
= 3dB measurement uncertainty
‡ K
wA
= 3dB measurement uncertainty
Installation and Lubrication
Size air supply line to ensure tool’s maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16606576 and table on page 2. Maintenance frequency is shown in a
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
7.
Coupling
2. Regulator
8.
Safety Air Fuse
3. Lubricator
9.
Oil
4. Emergency shut-off valve
10. Grease - during assembly
5. Hose diameter
11. Grease - through fitting
6. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
Original instructions are in English. Other languages are a translation of the original instructions.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest
Ingersoll Rand
Office or Distributor.
Summary of Contents for 7811G
Page 6: ...Notes...
Page 7: ...Notes...