WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fl uid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion resulting 

in severe injury or death. Ground pump and pumping 
system.
Sparks can ignite fl ammable material and vapors.
The pumping system and object being sprayed must 
be grounded when it is pumping, fl ushing, recirculat-
ing or spraying flammable materials such as paints, 
solvents, lacquers, etc. or used in a location where 
surrounding atmosphere is conducive to spontaneous 
combustion. Ground the dispensing valve or device, 
containers, hoses and any object to which material is 
being pumped.
Use the pump grounding screw terminal provided. 
Use ARO® part no. 66885-1 ground kit or connect a 
suitable ground wire (12 ga. minimum) to a good 
earth ground source.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static 
spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 3/4” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 HAZARDOUS PRESSURE. Can result in seri-

ous injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must 
comply with local and national laws and safety code 
requirements.
Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use mod-

els containing aluminum wetted parts with food prod-
ucts for human consumption. Plated parts can contain 
trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on me-

chanical stress only. Certain chemicals will signifi-
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be flex-
ible connections (such as hose), not rigid piped, 
and should be compatible with the substance being 
pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 
for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 
life.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark” pn \ 93616-1, Diaphragm 
Rupture” pn \ 93122.

y

y

y

y

y

EXCESSIVE AIR PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

Summary of Contents for 66M150-XXX-C

Page 1: ...aximumTemperature Limits diaphragm ball seal material E P R 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 t...

Page 2: ...Y AND PROPERTY DAMAGE Disconnect air supply line and relieve pressure from the system by opening dispensing valve or device and or carefully and slowly loosening and removing out let hose or piping fr...

Page 3: ...ices which could result in severe personal injury death or substantial property damage CAUTION Hazards or unsafe practices which could result in minor personal injury product or property damage NOTICE...

Page 4: ...O Ring Qty Mtl O Ring Qty Mtl XX2 637469 X2 94615 G 2 B Y325 16 4 B Y325 230 4 B XX9 637469 X9 94615 9 2 H Y328 16 4 T Y327 230 4 V XXB 637469 XB 94615 A 2 Sp Y328 16 4 T 92761 4 E COMMON PARTS Item...

Page 5: ...0 in lbs 27 1 31 6 Nm 29 nut 120 140 in lbs 13 6 15 8 Nm LUBRICATION SEALANTS c Apply Key Lube grease 93706 1 to all O rings U cups and mating parts d Apply Loctite 271 to threads PARTS LIST 66M150 XX...

Page 6: ...ring onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports Lubricate and carefully insert 111 spool Install 117 gasket and 107 plate Lubricate and ins...

Page 7: ...OVERTIGHTEN FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS c Apply Key Lube grease to all O rings U cups and mating parts d Apply Loctite 271 to th...

Page 8: ...pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling...