Ingersoll-Rand 635390 Series Operator'S Manual Download Page 2

63539XĆX

PA GE 2 OF 4

67150 CONTROL HANDLE / AGARRADERA DE CONTROL / MANETTE DE COMMANDE

H

Included in Repair Kit 67150Ć14.

Incluye el Juego de Reparación 67150Ć14.

Inclus dans la trousse de réparation 67150Ć14.

#

Apply Thread Lock.

Aplicar la Cerradura de Rosca.

Appliquer de l'enduit frein pour filets.

k

Use Mounting Grease.

Utilizar Grasa e Montaje.

Utiliser de la graisse d'assemblage.

FIGURE 2

FIGURA2

FIGURE 2

11

10 #

8

7

5

4

3

2

1

# 10

Rp 1/2 (1/2 Ć 14 B.S.P.)

13

k H

13

k H

9

H

6

H

12

H

Rp 1/2 (1/2 Ć 14 B.S.P.)

PARTS LIST / LISTA DE PIEZAS / LISTE DES PIECES

Item

Elmento

Article

Description

Descripción

Description

Qty

Cant.

Quan.

Number

Numero

Numero

Item

Elmento

Article

Description

Descripción

Description

Qty

Cant.

Quan.

Number

Numero

Numero

1 Handle Body

(1)

2 Trigger

(1)

3 Ball Bearing Swivel

(1)

4 Cam

(1)

5 Valve Sleeve

(1)

n

6 Valve Body

(1)

7 Valve Spring

(1)

8 Screen Filter

(1)

n

9 Valve

(1)

10 Screw

(2)

11 Washer

(2)

n

12 ``O" Ring

(1)

n

13 ``O" Ring

(2)

n

Included in Repair Kit

Incluye el Juego de Reparación
Inclus dans la trousse de réparation

67150Ć14

INSTALLATION

 NOTICE

Use Anaerobic Pipe Sealant on the threads when

making pipe connections with this control handle.

OPERATION

The electronic meter contains a microprocessor boardwhich is battery

poweredwith an expectedlife of 1 Ć 2 years, depending on usage.

FUNCTION: Depress the RESET button to reset the batch totalizer to

zero before each use. Squeeze the trigger handle to dispense the deĆ

siredamount of fluid.

The Meter shows two sets of digits in the display:

Units dispensed display in Pints, Quarts or Liters depending on the

model.

Meters are shippedwith the unit of measure programmedat the factory.

BATCH TOTAL

is the total liquiddispensedsince the last press of the

RESET button.

CUMULATIVE TOTAL

is the total of all fluidunits meteredsince the

meter power supply was connectedthe first time. The CUMULATIVE

total will not change with RESET.

A nonĆvolatile memory stores the Cumulative Total indefinitely in case

of a long absence of power.

CAUTION

 

DO NOT SUBMERGE THE DIGITAL METER

HEAD IN PETROLEUM SOLVENTS.

Solvents may attack the

adhesive used in assembly causing damage. Clean the meter usĆ

ing soap andwater only.

RECALIBRATION:

Refer to the Advanced Instructions in the meter

manual section of the meter manual to change calibration factor if necĆ

essary.

Assembly

Use only Anaerobic Pipe Sealant on (3) Swivel threads. Do not use

Teflon tape.