65
INGENIA IG4T
Cod. 420120235 REV. 1.2
FLOWN INSTALLATION
Flown configuration provides for the hanging of 1 or 2 IG4T speakers, where the
optional accessory DRK-IG allows the use of a shackle, and the combination of
DRK-IG with the optional truss adapter TA-IG allows fixing on a specific device,
such as a rig. When the speakers are in a flown configuration, it is very advisable to
use both power supply and signal linking, to reduce the complexity of connections,
as shown in the “
” section.
ATTENTION!
•
When used outdoors, anchor the speaker to prevent any
oscillations due to atmospheric agents and wind.
•
Never use the handles to suspend the speaker!
FLOOR INSTALLATION
It is possible a floor installation of 1 or 2 INGENIA IG4Ts using the accessory GSA-
IG. A mechanical fixing with screws or screw anchors suited to the type of flooring
is required.
INSTALLATION WITH WALL BRACKETS
INGENIA IG4T can be installed on a wall using the optional brackets WB-IG14.
Select the position so as to obtain optimal coverage. In the case of properly
installed dual vertical speaker (it is mandatory in this case to use LP-IG), consider
the possibility of using digital steering technology (see paragraph). For details,
refer to the instructions of WB-IG14.