PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

The appliance 
is not 
functioning 

1.

 

The plug is not 
connected to the 
socket 

2.

 

Electrical current is 
not arriving to the 
plug due to the 
fuse being faulty or 
the automatic 
power constrainer 

1.

 

Connect the 
plug to the 
socket 

2.

 

Change the 
fuse or connect 
to the 
automatic 
power 
constrainer 
again 

The appliance 
does not cool 
well 

3.

 

The position of the 
thermostat is in a 
low setting 

4.

 

The door is not 
closed or it has 
been opened very 
frequently 

5.

 

The ventilation 
grids of the 
appliance are 
blocked 

6.

 

The appliance is 
exposed directly to 
a strong heat 
source 

3.

 

Turn the 
thermostat to a 
colder position. 

4.

 

Ensure the door 
is not left open 

5.

 

Remove the 
blockage or 
obstruction 

6.

 

Change the 
location of the 
unit or protect 
it against the 
heat source 

The interior 
light is not 
functioning 

7.

 

The plug is not 
connected to the 
socket 

8.

 

Electrical current is 
not arriving to the 
plug due to the 
fuse being faulty or 
the automatic 
power constrainer 

9.

 

The light is loose 

 
10.The light is 
damaged  

7. Connect the plug 
to the socket 
 
8. Change the fuse or 
connect to the 
automatic power 
constrainer again 
 

9.

 

Fix the light 
correctly 

 
10. Replace the light 

 

Noisy 
Functioning 

11. The appliance has 
not been levelled 
correctly. 
 
12. Some of the 
interior pipes rub. 
 

11. Level the 
appliance. 
 
12. Separate the 
pipes 
 
 

Summary of Contents for AEX500TF/1P

Page 1: ...MANUAL OF INSTRUCTIONS...

Page 2: ...WARNINGS 3 INSTALLATION 4 REGULATION CONTROL 6 GOODS LOADING 7 EVAPORATOR DEFROSTING 8 CLEANING 9 DAMAGE INDICATIONS 10 NOTE PLEASE OPEN THE LAST PAGE OF THIS HANDBOOK...

Page 3: ...ed technical service personnel in the first instance notify your distributor It requires adequate and continuous ventilation lack of such can cause damage to the appliance and deterioration of foodstu...

Page 4: ...al characteristics of your appliance correspond to those of the domestic installation If the power supply cable is damaged it must be replaced by the special power supply cable type HO5 W F or HO5 WH2...

Page 5: ...the model Starting Plug in the appliance Press the interior lighting switch to ensure it is functioning Dependent on model Press the startup switch The switch should light up and you can hear the moto...

Page 6: ...rmostat in the appropriate direction according the representative scale This scale either directly indicates the centigrade degrees or a numerical scale that does not indicate degrees but serves as a...

Page 7: ...exceed the height of the evaporator in the expository showcases or the loading level in those appliances that is indicated Do NOT put hot food in the appliance Food or drink that have strong smells a...

Page 8: ...an be automatic or manual Manual Defrosting This is produced by disconnecting the appliance approximately every five days Automatic Defrosting Appliance with an automatic defrost function do not need...

Page 9: ...he mains It is very important to keep the condensing unit free of foreign bodies and is recommended to periodically clean it This will prevent problems with the function and an increase in power consu...

Page 10: ...lick noise it is necessary to disconnect the appliance to avoid greater breakdowns Then after an hour reconnect the appliance and if the noise persists contact the technical service department of your...

Page 11: ...irectly to a strong heat source 3 Turn the thermostat to a colder position 4 Ensure the door is not left open 5 Remove the blockage or obstruction 6 Change the location of the unit or protect it again...

Page 12: ...doors 17 The unit is not defrosting 14 Turn the thermostat controller to a colder position 15 Close doors correctly 16 Avoid frequent door opening 17 Consult the paragraph evaporator defrosting in th...

Reviews: