Infratech SL 1612 Installation, Use & Care Manual Download Page 5

Disconnect power at the breaker. Remove two screws from one end of trim and slide trim off opposite end. Remove  

grill by grasping it in the middle, flex grill up and lift it off. Unscrew and remove both end reflectors. Unhook element 

clips at each end of the heater and remove nuts from end of element to remove the existing quartz tube. Carefully 

install the new element. Remove one nut from end of the new element. Install wire by sliding high temperature ring 

terminal onto element screw and replace nut. Use a thin 11/32" wrench to hold inside nut. Nuts must make a tight 

connection. Close element clips over tube and reinstall end reflectors, and snap protective grill back in, then 

reinstall trim. 

REPLACEMENT ELEMENT INSTALLATION

NOTE:   Hold ceramic element firmly while tightening 

nut to prevent damage to element. Nut should 

be tightened snug. A loose connection can 

cause the element to short or fail prematurely. 

(Visit infratech-usa.com for video instructions)

Need help? 

To order replacement 

elements for your Infratech heating 

system, please contact us via phone

or visit our website. 

Consult label on back of heater 

for proper watts, voltage, and 

replacement part number. 

PART#         ELEMENT#            LENGTH                   WATTS   VOLTS      FITS MODELS

10-7025        E-1612-SL

22-3/8"  (0.6m)          1600       120          SL-1612 

10-7030        E-1624-SL

22-3/8"  (0.6m)          1600       240          SL-1624 

10-7035        E-2424-SL

35-3/8"  (0.9m)          2400       240          SL-2424 

10-7040        E-2428-SL

35-3/8"  (0.9m)          2400       208          SL-2428 

10-7055        E-3024-SL

56-3/8"  (1.4m)          3000       240          SL-3024 

10-7060        E-3028-SL 

56-3/8"  (1.4m)          3000       208          SL-3028 

10-7075        E-4024-SL

56-3/8"  (1.4m)          4000       240          SL-4024 

10-7080        E-4028-SL

56-3/8"  (1.4m)          4000       208          SL-4028

REPLACEMENT ELEMENTS

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

5

Heater must be installed with the quartz tube horizontally level. For maximum tube life, use a level to find the 

optimum position for the heater’s body. Always maintain the minimum clearances from the heater body to any 

combustible materials. 

11/32” OUTSIDE NUT

11/32” INSIDE NUT

(SNUG TO CERAMIC)

alfresco-heating.com

888-Warm-Glo

Summary of Contents for SL 1612

Page 1: ...ons 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ALL WEATHER W SERIES AND WD SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HE TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions ...

Page 2: ...th the local wiring codes Do not use if the heating element is damaged or cracked 2 READ ALL INSTRUCTIONS BEFORE USING HEATER Unit may be a source of possible shock NEVER attempt to service heater without disconnecting its power source Source of possible ignition High Temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 3 0 9m from the front of heater ...

Page 3: ...ode NEC and local codes for outdoor wiring Step 5 Use only wiring components UL CUL CE listed for outdoor use with IPX4 minimum rating INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS Connect power with flexible conduit or appropriate cord to allow heater to be swiveled The heater is drilled and threaded for standard conduit fittings The installing electrician will need to provide the appropriate rig...

Page 4: ...is required behind the plane of the face MODEL MIN SPACING BETWEEN BRACKETS SL 16XX 12 30 5cm SL 24XX 20 50 8cm SL 30XX 30 76 2cm SL 40XX 30 76 2cm SL Series Brackets are designed for two positive stop positions The Heater can be hung in a horizontal position using chains or custom brackets The Heater must be level but can be rotated around its horizontal axis Adjustable wall ceiling brackets are ...

Page 5: ...fail prematurely Visit infratech usa com for video instructions Need help To order replacement elements for your Infratech heating system please contact us via phone or visit our website Consult label on back of heater for proper watts voltage and replacement part number PART ELEMENT LENGTH WATTS VOLTS FITS MODELS 10 7025 E 1612 SL 22 3 8 0 6m 1600 120 SL 1612 10 7030 E 1624 SL 22 3 8 0 6m 1600 24...

Page 6: ... x 8 2 4m x 2 4m SL 2424 2 400 7 9 2 1m 2 7m 7 x 7 2 1m x 2 1m 5 x 5 1 5m x 1 5m 9 x 9 2 7m x 2 7m SL 3024 3 000 7 9 2 1m 2 7m 8 x 8 2 4m x 2 4m 6 x 6 1 8m x 1 8m 10 x 10 3 0m x 3 0m SL 4024 4 000 8 11 2 4m 3 4m 10 x 10 3 0m x 3 0m 8 x 8 2 4m x 2 4m 12 x 12 3 7m x 3 7m MODEL WATTS MOUNTING HEIGHT AVERAGE COLD PROTECTED SL 1612 SS 1 600 6 8 1 8m 2 4m 6 x 6 1 8m x 1 8m 4 x 4 1 2m x 1 2m 8 x 8 2 4m x...

Page 7: ...rs are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it will last longer...

Page 8: ...ural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property...

Reviews: