16
IM110822
RD: AUGUST 2011
RL; 1A
BA
InfraSave IEP-4024 Manual
Heat Lamp Replacement
:
…
continued
Step 4
Remove the 2 Phillips screws that fasten the electrical con-
nection box front face plate in place.
Step 5
Slide the connection box front face plate out from the electri-
cal connection box.
Step 6
Slide power cord retainer plate from electrical connection box
(top surface).
Step 7
Loosen screws in terminal block to remove wires as required:
RED wires connect to Lamp #1 (closer to connection box)
BLUE wires connect to Lamp #2 (further end from box)
Do not disconnect power supply wires
Loosen the threaded clamping collar on the Liquid Tight
Connector located behind the wiring terminal
Pull wires out through the Liquid Tight Connector and top
of electrical connection box
Step 8
Slide lamp wires out of electrical connection box.
Set electrical connection box aside.
Electrical
Connection
Box
Loosen screws as required