23
CD1-k – User Guide
Chapter 5 – Troubleshooting & maintenance
2 - ERROR RESET
A stored error can be cancelled as follows:
•
by means of the parameter setting software
Visual Amplifier Setup
, via the serial link RS232,
•
by means of the
RESET
function issued from the
CANopen bus
,
•
by switching off the amplifier supply.
3 - OPERATION PROBLEMS
3.1 - MOTOR DOES NOT MOVE
•
Check that the amplifier is on.
•
Check for no error on the amplifier.
•
Check the wiring of the logic command inputs.
•
Check that the amplifier is enabled.
3.2 - MOTOR ENABLED BUT LITTLE TORQUE
•
Check
the
Max. current
and
Rated current
parameters.
3.3 - SHAFT LOCKED – ERRATIC OSCILLATIONS - ROTATION AT MAXIMUM SPEED
•
Check the resolver or encoder wiring on the amplifier connector as well as the mechanical fastening of the
position feedback sensor on the motor.
•
Check for the correct motor selection in the
MOTOR LIST
module.
•
Check the value of the
Motor parameters
in the
Advanced Functions
menu and renew the
AUTO-PHASING
command, with unloaded motor, if required.
3.4 - DISCONTINUOUS MOTOR ROTATIONS WITH ZERO TORQUE POSITIONS
•
Check the wiring of the three phases between motor and amplifier.
3.5 - LOUD CRACKLING NOISE IN THE MOTOR AT STANDSTILL
•
Check that the Motor - Amplifier - Host system ground connections comply with the wiring recommendations.
•
Check the rigidity of the mechanical transmission chain between motor and load (backlashes and elasticity in
the gears and couplings).
•
Start a new
Autotuning
procedure by selecting a lower bandwidth than the initial one.
4 - SERVICE AND MAINTENANCE
When exchanging a amplifier on a machine, proceed as follows:
•
Check that the new amplifier has got the same voltage and current ratings as well as the same hardware
configuration as the one to be replaced.
•
Reload and save the parameters of the old amplifier via the serial link or the
CANopen
interface.
The new amplifier is now ready for operation.