Wall Installation 

 

The Hanging Plates (B) should be attached to 
the shorter side of the heating Panel for vertical 
Installation and to the longer side for a 
horizontal installation. The plates are attached 
by using the Bolts (C) 

– 2 bolts per plate. 

 

 

make sure that the corner of the panel 
where the cable is attached is 

not

 used for 

mounting the plates. 

 

and that the slots in each of the plates are 
mounted in the same direction (see picture) 

 

and that the bolts (C) are only hand tight to 
ensure no damage to the frame. 

 
 
 
 
Screw the two bolts (D) into the integrated nuts 
found in the opposite side of the frame from 
where the plates are attached. These bolts 
insure that the correct distance from wall to the 
back of the panel is adhered too. 
 
 
 
 
 
Measure the distance (X) between the slots and 
transfer this measurement to the wall where the 
panel is to be installed. Use a Level to ensure 
that the marks for drilling are level. 
 
 

Drywall Installation 

Drill each of the holes with a 5/8-hole drill thru 
the Drywall, or use the enclosed Wood screws. 
if mounted to a stud in the Wall.  

On Masonry

 use the Anchor and Wood Screws.  

 

 
Insert the Toggle bolts (E) into the holes; make sure that both are fully 
inserted and tightened against the Wall with the Nut leave the Bolt 
extended from the Wall 1 inch, use the wood screws for wood studs.

 

 
Screw in the Mounting Screws (E) up to the flange making sure that the 
hooked part of the screw is vertical. 
 
Lift the Heating Panel onto the Mounting Screws and then slide it to one 
side insuring that both screws are in the dogleg part of the slots. This 
insures that the heating panel cannot be easily removed from its 
position.                                                                                               

 
 
 

 
 

 

 

 

Summary of Contents for US-64-M

Page 1: ...infraNOMIC usa LLC INFRARED HEATING PANELS Operating and Installation Instructions Installation instructions for framed models infraNOMIC usa LLC 10441 Washington Hwy Glen Allen Virginia 23059 USA 1 ...

Page 2: ...ost efficient way Please make sure that you use the heater exactly as per the following instructions the adherence to these instructions is a pre condition to the manufactures liability regarding any guarantee cases After completion please store these instructions in a safe place so that they can be used again if necessary and can be given to another user if the panel changes hands Contents Thank ...

Page 3: ...diately disconnect the panel from the power supply and contact our service department Do not pull clamp or in any other way damage the connecting cable attached to the panel If the supply cord is damaged it must be replaced by the manufacturer to avoid a hazard Do not attempt to carry out any repairs changes or modifications to the heater Before any assembly or cleaning work is carried out disconn...

Page 4: ...correctly WARNING Make sure that the packing material is kept away from babies and small children as suffocation can result if placed over their mouths or noses Installation WARNING Please read the section regarding Basic Rules for Safety and details involving the installation location the information regarding safe distances and the operation of the panel Please take note of the following additio...

Page 5: ...adhered too Measure the distance X between the slots and transfer this measurement to the wall where the panel is to be installed Use a Level to ensure that the marks for drilling are level Drywall Installation Drill each of the holes with a 5 8 hole drill thru the Drywall or use the enclosed Wood screws if mounted to a stud in the Wall On Masonry use the Anchor and Wood Screws Insert the Toggle b...

Page 6: ...the power consumption of the heater The power consumption of your heater is included in the information on the nameplate of the heater to be found on the back of the panel Tips for correct use When the heater is turned on at first it is possible that for a short while you may be aware of a distinct sweet smell This is not harmful to health and if present is caused by the vaporisation of silicon in...

Page 7: ...f all current models are listed in the Data Page see page 9 The units comply with the test requirements of the European Low Voltage specifications 2006 95 EG and the harmonised Product Standards EN 60335 1 and EN 60335 2 30 and are marked with a CE Conformity Label Warranty and Service The heating panels by infraNOMIC usa LLC come with a warranty period of 5 years after the purchase date If these ...

Page 8: ... kg 24 x 36 inch US 93 M 530 118 129 ft 11 12 m 24 2 lb 11 kg 24 x 48 inch US 76 M 700 172 193 ft 16 18 m 30 8 lb 14 kg 24 x 60 inch US 96 M 900 215 236 ft 20 22 m 33 lb 15 kg More sizes later Frameless SL Power Size of room to be heated Metal Backing X Size w x h Model Watt approx Weight Due to the nature of tempered safety glass variations of the planetary may occur These values serve as a rough...

Page 9: ......

Reviews: