11 

 

4. Technical specifications   

  

Smart   

Charger S 24 

Smart   

Charger S 48 

Smart 

  Charger S 72 

GENERAL CHARACTERISTICS 

Output voltage 

24 Vdc 

48 Vdc 

72 Vdc 

PROTECTION   

Full protection 

Over-voltage / Short circuit / Reversal polarity 

PHYSICAL CHARACTERISTICS 

Dimensions - 

DxWxH (mm)

 

220 x 150 x 83 mm 

Net weight 

kg

 

2,5 

INPUT TECHNICAL CHARACTERISTICS 

Nominal input voltage 

230 VAC 

Voltage range 

110-280 VAC 

Frequency range 

50/60 Hz 

Nominal RMS Current 

1.0A 

2.0A 

3.0A 

OUPUT TECHNICAL CHARACTERISTICS   

Charging Power 

144 W 

288 W 

432 W 

Floating charging voltage 

27,4 Vdc 

54,7 Vdc 

82,1 Vdc 

Boost charging voltage 

28,8 Vdc 

57,6 Vdc 

86,4 Vdc 

Output charge current 

6 A ± 0.6 A (1A/2A/4A/6A selectable) 

INDICATORS 

Charger On 

Green LED lighting 

Boost charging status   

Yellow LED flashing  

Floating charging statuts 

Green LED lighting   

Battery reversal 

Red LED lighting  

ENVIRONMENT 

Ideal environment 

0-40°C, 0-95% of   

relative humidity (without condensation) 

Noise level 

Less than 50dB 

NORMS 

Standard 

CE 

EMC 

EN 55022 :2010+AC : 2011 ; EN 61000-3-2 :2014 ; EN 61000-3-3 :2013 ; EN 

55024 :2010 (EN61000-4-2 :2009 ; EN61000-4-3 :2006+A2 :2010 ; EN 

61000-4-4 :2012 ; EN 61000-4-5 :2006 ; EN 61000-4-6 :2014 ; EN 

61000-4-11 :2004 

LVD 

EN 60950-1 :2006+A11 :2009 + A1 :2010+A12 :2011+A2 :2013 

SALES INFO 

Warranty   

2 years 

Gencods 

3700085 61139 5 

3700085 61140 1 

3700085 61141 8 

Summary of Contents for 3700085 61139 5

Page 1: ...User Manual Manuel utilisateur 24 48 72 Vdc...

Page 2: ...700 Orvault France www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 fax 33 0 2 40 94 29 51 hotline infosec fr 10 15 AA 59 203 04 2 E En ng gl li is sh h V Ve er rs si io on n p p3 3 V Ve er rs si i...

Page 3: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault France www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 fax 33 0 2 40 94 29 51 hotline infosec fr 10 15 AA 59 203 04 3 English version...

Page 4: ...cessible To isolate the charger from AC input remove the plug from the utility power outlet To reduce the risk of electric shock disconnect both AC and DC power from the charger before attempting any...

Page 5: ...Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries termin...

Page 6: ...n you require on the identification plate on the back of the unit If convenient you may enter the details in the following box Model Serial number Date of purchase Smart Charger S 24 Vdc Smart Charger...

Page 7: ...move the Charger from its package and inspect it for damage that may have occurred during shipping If any damage is discovered re pack the unit and return it to the place of purchase Below is the DC c...

Page 8: ...ct the Smart charger S Step 1 Switch off the charger before connect the battery Step 2 Apply AC power to the charger unit This charger can either work alone to charge batteries or work with UPS to cha...

Page 9: ...or Refer to below chart There are four selections for charging current 1A 2A 4A and 6A The charging current of the battery set is about 1 10 times the total capacity of the battery set Example 1 UPS E...

Page 10: ...5 AA 59 203 04 10 3 1 Front face 1 Battery Fuse 2 LED indicators Indicators Status ON LED is lighting Charger is ON CHARGING LED is lighting Boost charging FULL CHG LED is lighting Fully charged BAT R...

Page 11: ...CHNICAL CHARACTERISTICS Charging Power 144 W 288 W 432 W Floating charging voltage 27 4 Vdc 54 7 Vdc 82 1 Vdc Boost charging voltage 28 8 Vdc 57 6 Vdc 86 4 Vdc Output charge current 6 A 0 6 A 1A 2A 4A...

Page 12: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault France www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 fax 33 0 2 40 94 29 51 hotline infosec fr 10 15 AA 59 203 04 12 Version Fran aise...

Page 13: ...outes les r parations doivent tre effectu es uniquement par des techniciens qualifi s La prise d alimentation secteur doit tre proche de l appareil et facilement accessible Pour isoler le Smart Charge...

Page 14: ...qu ils ne puissent faire tr bucher personne Ne laisser aucun r cipient contenant un liquide sur le Smart Charger S ou pr s de lui Le Smart Charger S a t con u pour les onduleurs Il ne doit pas tre ut...

Page 15: ...faible et ne pas d passer 90 Eviter toute exposition directe aux rayonnements solaires ou toute autre source de chaleur Le chargeur ne doit tre utilis qu en int rieur En cas d incendie merci d utilise...

Page 16: ...ompatibilit lectromagn tique IMPORTANT Les Smart Charger S appartiennent la cat gorie des quipements lectriques et lectroniques En fin de vie ces produits doivent faire l objet d une collecte s lectiv...

Page 17: ...roit s r pour une utilisation future L emballage contient 1 Smart Charger S 1 c ble de raccordement l armoire batterie 1 c ble d alimentation 1 guide utilisateur Voici ci dessous les couleurs associ e...

Page 18: ...t Charger S avant de le connecter aux batteries Etape 2 Mettre le Smart Charger S sous tension Il peut aussi bien travailler seul pour recharger les batteries ou avec l onduleur pour charger les batte...

Page 19: ...tableau ci dessous Quatre s lections pour le courant de charge sont disponibles 1A 2A 4A et 6A Le courant de charge du jeu de batterie est environ 1 10 fois la capacit totale du jeu de batterie Exempl...

Page 20: ...t 1 Fusible de batterie 2 Indicateurs LED Indicateurs Statut L indicateur ON est allum Le Smart Charger S est allum L indicateur CHARGING est allum Chargement en cours L indicateur FULL CHG L indicate...

Page 21: ...g 27 4 Vdc 54 7 Vdc 82 1 Vdc Tension de charge en mode Boost 28 8 Vdc 57 6 Vdc 86 4 Vdc Courant de charge de sortie 6 A 0 6 A 1A 2A 4A 6A s lectionnable INDICATEURS Smart Charger S allum LED verte all...

Page 22: ...INFOSEC UPS SYSTEM 4 rue de la Rigoti re 44700 Orvault France www infosec ups com Hot Line Tel 33 0 2 40 76 15 82 fax 33 0 2 40 94 29 51 hotline infosec fr 10 15 AA 59 203 04 22...

Reviews: