34
Cleaning the dust filters
In dirty or dusty environments, the dust filters can become clogged, causing
high temperatures inside the lamp module. These high temperatures can
impact lamp performance and operating life. Routine maintenance to
remove dust and dirt from the filters lowers the lamp operating tempera-
ture and prolongs lamp life. To maximize lamp life you will need to clean
the filters every 250 hours. Lamp filter maintenance may need to occur more
often than 250 hours depending on your installation/use environment.
There are two filters, one mesh filter attached to the dust filter door and one
metal grid filter adjacent to the lamp door.
1
Turn off the projector and unplug the power cable.
2
Wait 60 minutes to allow the projector to cool thoroughly.
WARNING
: To avoid burns, allow the projector to cool for at least 60
minutes before you clean or replace the dust filter
.
3
Turn the projector upside down and remove the lamp door. See page 32.
4
Remove the dust filter door.
5
Clean the filter using a vacuum set on low power.
6
Replace the dust filter door and the lamp door.
7
Vacuum the non-removable metal grid filter adjacent to the lamp door.
Using the security lock
The projector has a security lock for use with a cable lock system. See
“Accessories” on page 35 for ordering information. Refer to the information
that came with the lock for instructions on how to use it.
audio in
serial control
Pr
Pb
Y
trigger
turn off and unplug
the projector
wait 60 minutes
remove filter door
vacuum filter
metal grid filter
audio in
serial control
Pr
Pb
Y
trigger
security lock