RS-232 commands 

Communication Configuration

Visit our website for additional RS-232 settings and information.

To control this projector via RS-232, connect a null modem cable and set the 
control system serial port settings to match the following communication 
configuration: 

Command Format

All commands consist of 3 alpha characters followed by a request, all 
enclosed in parentheses. The request can be a read request (indicated by a 
"?") or a write request (indicated by 1 to 4 ASCII digits).

A read request example: 

(AAA?) where

( starts the command

AAA denotes the command

? denotes the read request

) ends the command

A read command returns the range and the current setting, for example:

A write request example: 

(AAA####) where

(starts the command

AAA denotes the command

#### denotes the value to be written 

(leading zeros not necessary)

) ends the command

Some commands have ranges, while others are absolute. If a number greater 
than the maximum range is received, it is automatically set to the maximum 
number for that function. If a command is received that is not understood, a 
"?" is returned. With absolute settings, "0" is off, 1-9999 is on. The one excep-
tion is the Power command, where 0 is off and 1 is on.

To assure the projector can process a command, wait 3 seconds before enter-
ing the next command.

RS-232 Port Settings

Setting

Value

Bits per second

19,200 

Data bits

Parity

None 

Stop bits

Flow control

None 

Emulation

VT100 

Read Command Examples

Function

Command

Response 

Brightness

(BRT?)

(96-160,128)

Volume

(VOL?)

(0-32, 0) 

Lamp Hours

(LMP?)

(0-65534, 42) 

Summary of Contents for LP860

Page 1: ...ting for example A write request example AAA where starts the command AAA denotes the command denotes the value to be written leading zeros not necessary ends the command Some commands have ranges while others are absolute If a number greater than the maximum range is received it is automatically set to the maximum number for that function If a command is received that is not understood a is retur...

Page 2: ... the menu bar position since the On screen Display is not an exact match of values For example Step 2 changes the data by 2 through the CLI Command Line Interface The menu bar is up or down by 1 Write Command Examples Function Command Response Brightness BRT140 Sets the brightness to 140 Power PWR0 Turns power off Power PWR1 Turns power on Function Com mand Min Max De fault Step Auto Power 0 disab...

Page 3: ...4 video 3 5 computer 3 DSC at RW 0 5 0 Startup Logo 0 blank screen 1 default 2 captured DSU at RW 0 2 1 Function Com mand Min Max De fault Step Effect 0 blank 1 mute 2 aspect ratio 3 source 4 auto image 5 freeze 6 zoom 7 PiP Source EFK at RW 0 8 7 1 Horizontal Position HPS at RW def 50 def 50 auto 1 Language 0 English 1 French 2 German 3 Spanish 4 Traditional Chinese 5 Japanese 6 Korean 7 Portugue...

Page 4: ...Phase MSS at RW 0 31 18 1 Mute 0 disable 1 enable MTE at RW 0 1 0 Tracking MTS at RW def 128 def 128 auto 1 Function Com mand Min Max De fault Step Menu Navigation 0 up 1 down 4 select NAV at W 0 4 1 NND 0 disable 1 enable NND at RW 0 1 1 Unit Total Time On ONL at R 0 214748 3646 0 Overscan 0 disable 1 enable OVS at RW 0 1 0 Presets 0 presentation 1 photography 2 film 3 video 10 user 1 11 user 2 1...

Page 5: ...ave 0 5 minutes 1 10 minutes 2 15 minutes 3 20 minutes 4 25 minutes 5 30 minutes SSV at RW 0 5 0 1 Function Com mand Min Max De fault Step Color Temp 0 9300K 1 6500K 2 7200K 3 User TMP at RW 0 3 2 Tint TNT at RW 114 142 128 1 Volume VOL at RW 0 32 16 1 Vertical Position VPS at RW 0 def auto x 2 auto 1 Video Standard 0 Auto 1 NTSC 2 PAL 3 SECAM VSU at RW 0 3 0 IR Receiver front 0 disable 1 enable I...

Page 6: ...in Max De fault Step PiP Size Selection 0 off 1 small 2 medium 3 large PSS at RW 0 3 0 PiP Input 3 video 2 1 video 3 PIN at RW 3 4 3 PiP Position 0 upper left 1 upper right 2 lower left 3 lower right 10 user PPO at RW 0 4 2 ...

Reviews: