background image

For the Infoblox-250-A  Appliance 

9

Installing an Appliance

Follow these instructions to rack mount the appliance, connect it to a power source, and cable it to a network. 
Review the 

Infoblox Safety Guide

 and follow the necessary precautions before you start.

Rack Mounting

The appliance mounts into a standard 19” (48 cms) equipment rack. In addition to the screws and brackets that ship 
with the product, you also need a screwdriver with a cross-headed tip.

Attach the brackets to the appliance, and mount it to an equipment rack.

1.

Remove the four screws that ship attached to the left and right sides of the appliance—two screws per side.

2.

Remove the pair of brackets from the accessory kit that also ships with the appliance.

3.

Position one bracket so that the two holes in the bracket align with two of the holes on one side of the 
appliance.

Note: 

There are five evenly spaced holes on each side of the appliance. You can secure the brackets to any two 

adjacent holes so that you can mount the appliance more or less deeply in the rack.

4.

Secure the bracket to the appliance with two of the screws that you removed previously.

5.

Secure the second bracket in the same position on the other side of the appliance.

6.

Attach the brackets to the equipment rack using the screws from the accessory kit.

Powering the Appliance

Use the power cable that ships with the Infoblox appliance to connect it to a power source. 

1.

Make sure that the power switch on the appliance is turned off.

2.

Connect a power cable between the power connector on the back of the appliance and a properly grounded and 
rated power circuit that meets the provisions of the current edition of the National Electrical Code, or other 
wiring rules that apply to your location. Make sure that the outlet is near the appliance and is easily accessible. 

3.

Turn on the power switch.

Summary of Contents for Infoblox-250-A

Page 1: ...omissions which may be present in this document or from use of this document This document is an unpublished work protected by the United States copyright laws and is proprietary to Infoblox Inc Disclosure copying reproduction merger translation modification enhancement or use of this document by anyone other than authorized employees authorized users or licensees of Infoblox Inc without the prior...

Page 2: ...information refer to the Infoblox website or contact Infoblox Technical Support Company Information Infoblox is located at 4750 Patrick Henry Drive Santa Clara CA 95054 1851 USA Web www infoblox com www infoblox com support Phone 408 625 4200 Toll Free 888 463 6259 Outside North America 1 408 716 4300 Fax 408 625 4201 Product Information Hardware Models Infoblox 550 A 1050 A 1550 A 1552 A 1852 A a...

Page 3: ...oblox approach combines the simplicity of appliances with the power of advanced distributed database technology to control and automate services while achieving availability manageability visibility and control unparalleled by conventional solutions based on legacy technologies You can configure and manage the Infoblox 250 A through an easy to use Infoblox GUI that works seamlessly in Windows Linu...

Page 4: ...nnector Pin Assignments on page 6 Figure 2 Infoblox 250 A Front Panel Table 1 Front Panel Components Component Description USB Port Reserved for future use Console Port A male DB 9 serial port for a console connection to change basic configuration settings and view basic system functions through the CLI command line interface Use the serial cable and connection adapters that ship with the applianc...

Page 5: ...gh availability pair connects to the network using a VIP virtual IP address HA pair nodes also use their HA ports for VRRP Virtual Router Redundancy Protocol advertisements LAN1 Port A 10 100 1000 Mbps gigabit Ethernet port that connects a NIOS appliance to the network You must use the LAN1 port to set up the appliance initially It handles all traffic if you do not enable the MGMT and LAN2 ports T...

Page 6: ...ansmit data and the twisted pair connecting to pins 3 and 6 receive data For 1000Base T connections all four twisted pair wires are used for bidirectional traffic Figure 4 Connector Pin Assignments 2 1 3 4 5 6 7 8 9 2 1 3 4 6 5 7 8 7 8 6 5 3 4 2 1 DB 9 Connector Pin Assignments RJ 45 Connector Pin Assignments Pin 10Base T 100Base T Signal 1000Base T Signal T568A Straight Through Wire Color T568B S...

Page 7: ...nge within which the appliance circuitry can operate Component Description Model Number An identifier of the hardware model type and software type Serial Number The serial number of the appliance Use it to register the appliance to obtain software upgrades and technical support services Air Vent An air vent that allows warm air to flow out of the appliance Do not obstruct Fan A fan to help maintai...

Page 8: ... 240 VAC switchable 47 63 HZ 3 A Europe 208 265 VAC switchable 47 63 HZ 2 A Output Power 250 watts Power plug and cable specifications by region Region Plug Type Cable Type Max Power Rating Max Temperature Rating North America NEMA5 15P 3 prong male plug VCTF 3C 18 AWG 7A 125 V 75 C Japan NEMA5 15P 3 prong male plug VCFI 3G 12A 125 V 60 C Europe CEE7 standard VII 2 prong male plug H05VV F 6A 250 V...

Page 9: ...e side of the appliance Note There are five evenly spaced holes on each side of the appliance You can secure the brackets to any two adjacent holes so that you can mount the appliance more or less deeply in the rack 4 Secure the bracket to the appliance with two of the screws that you removed previously 5 Secure the second bracket in the same position on the other side of the appliance 6 Attach th...

Page 10: ...col works properly configure the following settings at the port level for all the connecting switch ports HA LAN1 and LAN2 Spanning Tree Protocol Disable For vendor specific information search for HA in the Infoblox Knowledge Base system at http www infoblox com en support support center login html Trunking Disable EtherChannel Disable IGMP Snooping Disable Port Channeling Disable Speed and Duplex...

Page 11: ...oblox appliance Table 1 Software and Hardware Requirements for the Management System Management System Software Requirements Management System Hardware Requirements Infoblox GUI ACCESS Microsoft Internet Explorer 8 0 or Mozilla Firefox 3 5 on Microsoft Windows 7 Microsoft Internet Explorer 7 0 and 8 0 or Mozilla Firefox 3 5 on Microsoft Windows Vista Microsoft Internet Explorer 7 0 and 8 0 or Mozi...

Page 12: ...l network settings using the Infoblox CLI Note Only a properly grounded USB to Serial dongle is allowed to connect to the serial console port If the dongle is connected to a laptop this laptop must be grounded properly as well Failure to do so may result in damage to the serial console port of the Infoblox appliance Infoblox is not responsible for such damage 1 Connect a console cable from the con...

Page 13: ...n process This is normal because the NIOS appliance generates a self signed certificate when it first starts and your browser does not have a trusted CA certificate or a cached NIOS appliance server certificate saved from an earlier connection to authenticate the NIOS appliance certificate Also the hostname in the default certificate is www infoblox com which is unlikely to match the hostname of y...

Page 14: ...when you make an HTTPS connection to the HA pair Settings Enter your information here Grid Name Shared Secret Host Name Grid Master s IP Address LAN1 Port IP Address and Netmask Gateway IP Address Port Settings Admin Password Local Date Time and Time Zone or NTP Server IP Address Settings Enter your information here System Name Shared Secret Host Name Virtual Router ID VIP Virtual IP Address and N...

Page 15: ... the Infoblox GUI When an Infoblox appliance functions as an independent appliance you launch System Manager to access the Infoblox GUI When the appliance is in a grid you log in to the grid master and launch Grid Manager Figure 1 Infoblox GUI Overview Finder Panel Workspace Toolbar Help panel System Messages Breadcrumbs Navigation Global Search ...

Page 16: ...ig Perform a DNS lookup and print the results exit Exit command interpreter help Display help ping Send ICMP ECHO quit Exit command interpreter reboot Reboot device reset Reset system settings set Set current system settings show Show current system settings shutdown Shutdown device traceroute Route path diagnostic ddns_add Send DDNS update to add a record ddns_delete Send DDNS update to delete a ...

Reviews: