Accessing the Appliance

The management system is the computer from which you configure and monitor the Infoblox appliance. You can 
access the appliance from the management system remotely across an Ethernet network or directly through a serial 
cable. 

After completing the steps in 

Cabling the Appliance to a Network

 on page 12, you can make an HTTPS connection to 

the appliance and access the Infoblox GUI using one of the supported browsers. 

Alternatively, you can make an SSHv2 connection and access the CLI through an SSHv2 client. You can also access 
the CLI by connecting a serial cable directly from the console port of a management system to the console port on 
the appliance, and then using a terminal emulation program.

The management system must meet the following requirements to operate an Infoblox appliance. 

Table 1  

Software and Hardware Requirements for the Management System

Management System Software Requirements

Management System Hardware Requirements

Infoblox GUI ACCESS

Microsoft

®

 Internet Explorer

®

 8.0+ or Mozilla 

Firefox 3.5 + on Microsoft Windows 7

®

Microsoft Internet Explorer

®

 7.0+ and 8.0+ or 

Mozilla Firefox 3.5 + on Microsoft Windows Vista

®

Microsoft Internet Explorer

®

 7.0+ and 8.0+ or 

Mozilla Firefox 3.5 + on Microsoft Windows XP

® 

(SP2+)

Mozilla Firefox 3.5 + on Red Hat

®

 Enterprise Linux

®

 

or Fedora Core 8 and higher

Safari 3.2+ and 4.x+ on Apple Mac OS

®

 X v10.5 

and higher

CLI ACCESS

Secure Socket Shell (SSH) client that supports 
SSHv2

Terminal emulation program, such as minicom or 
Hilgraeve Hyperterminal

®

.

Minimum System:

 

 

500 MHz CPU with 256 MB RAM available to the 
Infoblox GUI, and 256 Kbps connectivity to an 
Infoblox appliance

Recommended System:

 

 

1 GHz (or higher) CPU with 512 MB RAM available 
for the Infoblox GUI, and network connectivity to an 
Infoblox appliance

Monitor Resolution: 

 

Minimum: 1024 x 768 
Recommended: 1280 x 800 or better

Summary of Contents for Infoblox-1852-A

Page 1: ...ical errors or omissions which may be present in this document or from use of this document This document is an unpublished work protected by the United States copyright laws and is proprietary to Inf...

Page 2: ...rmation refer to the Infoblox website or contact Infoblox Technical Support Company Information Infoblox is located at 4750 Patrick Henry Drive Santa Clara CA 95054 1851 USA Web www infoblox com www i...

Page 3: ...y of appliances with the power of advanced distributed database technology to control and automate services while achieving availability manageability visibility and control unparalleled by convention...

Page 4: ...dicator lights The back panel components include the air vent and redundant power supplies which have power connectors on off switches and fans Front Panel The panel components are shown in Figure 2 a...

Page 5: ...o a laptop this laptop must be grounded properly as well Failure to do so may result in damage to the serial console port of the Infoblox appliance Infoblox is not responsible for such damage Drive In...

Page 6: ...ou can use the RJ 45 rollover cable and two female RJ 45 to female DB 9 adapters that ship with the appliance or a female DB 9 to female DB 9 null modem cable The RJ 45 pin assignments follow IEEE 802...

Page 7: ...hite Green 4 not used BI_DC Blue Blue 5 not used BI_DC White Blue White Blue 6 Receive BI_DB Orange Green 7 not used BI_DD White Brown White Brown 8 not used BI_DD Brown Brown Male DB 9 Console Port R...

Page 8: ...he power supply has power It glows red when the power supply is not fully seated or has failed It is off when the power supply has no power On Off Switch A power switch to turn the power supply on and...

Page 9: ...ns 1 75 H x 17 4 W x 22 D 4 44 cms H x 44 19 cms W x 55 88 cms D Weight Approximately 25 pounds 11 33 kg Ethernet Ports MGMT HA LAN1 LAN2 auto sensing 10Base T 100Base T 1000Base T Serial Port DB 9 96...

Page 10: ...I 3G 12A 125 V 60 C Europe CEE7 standard VII 2 prong male plug H05VV F 6A 250 V 70 C United Kingdom LP 60L3 prongmale plug with fuse H05VV F 10A 250 V 70 C China RVV 300 500 3C X 1 00mmSQ IEC 320 C 13...

Page 11: ...the appliance 2 Position one bracket so that the two holes in the bracket align with two of the holes on one side of the appliance Note There are three sets of holes on each side of the appliance You...

Page 12: ...e the problem 3 To ensure that VRRP Virtual Router Redundancy Protocol works properly configure the following settings at the port level for all the connecting switch ports HA LAN1 and LAN2 Spanning T...

Page 13: ...te that the power supply is fully seated in the bay is powered on and is functioning properly The LED glows red to indicate the power supply is not fully seated or has failed The LED is off when the p...

Page 14: ...Installing an Appliance 14 Infoblox Installation Guide...

Page 15: ...blox appliance Table 1 Software and Hardware Requirements for the Management System Management System Software Requirements Management System Hardware Requirements Infoblox GUI ACCESS Microsoft Intern...

Page 16: ...network settings using the Infoblox CLI Note Only a properly grounded USB to Serial dongle is allowed to connect to the serial console port If the dongle is connected to a laptop this laptop must be...

Page 17: ...n process This is normal because the NIOS appliance generates a self signed certificate when it first starts and your browser does not have a trusted CA certificate or a cached NIOS appliance server c...

Page 18: ...If you configured an HA pair use the VIP address when you make an HTTPS connection to the HA pair Settings Enter your information here Grid Name Shared Secret Host Name Grid Master s IP Address LAN1 P...

Page 19: ...the Infoblox GUI When an Infoblox appliance functions as an independent appliance you launch System Manager to access the Infoblox GUI When the appliance is in a grid you log in to the grid master and...

Page 20: ...g Perform a DNS lookup and print the results exit Exit command interpreter help Display help ping Send ICMP ECHO quit Exit command interpreter reboot Reboot device reset Reset system settings set Set...

Reviews: