CONTROL page

 

 

 

Display System Sync:

 When the toggle is in 

enable

  position, the display 

 

on/off subroutine will run the system subroutine on/off every time. (see section 7)

 

 

Summary of Contents for WP200-Kit

Page 1: ...e 2020 01 06 Page 1 26 1 Record page No Revised summary description Version Revise person Revised Date 1 Initial version 1 0 Alex 2020 01 02 2 Connected the Auto System function description V1 1 Alex...

Page 2: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 2 26 2 Multi function AV intelligent education system Model WP200 Kit VER 1 1...

Page 3: ...product contains sensitive electrical components that may be damaged by electrical spikes surges electric shock lighting strikes etc Use of surge protection systems is highly recommended in order to...

Page 4: ...The product supports Web GUI and panel button control Transmitter support HDCP 1 4 HDCP2 2 and can be switched manually auto hybrid or priority And the maximum distance can be up to 70m at 1920x1200 6...

Page 5: ...and DTS HD Master Audio HDBaseT over a single CAT5e 6 7 cable up to 230ft 70m distance Support multi VESA Standard VGA formats input Supports MIC input 2x30watts 4 ohms amplifier output Supports inter...

Page 6: ...nnections Inputs 2x HDMI IN Type A 19 pin female 1x VGA DB15 VGA female 1x AUDIO IN 3 5mm Stereo Mini jack 1x RS 232 POWER RJ45 Outputs 1x HDBaseT Out RJ45 Receiver Inputs 1x HDBaseT In RJ45 1x MIC IN...

Page 7: ...P200 Kit User Manual Effective Date 2020 01 06 Page 7 26 7 Operating Temperature 32 104 F 0 40 C Storage Temperature 4 140 F 20 60 C Relative Humidity 20 90 RH no condensation 5 Operation Controls and...

Page 8: ...1 LED HDMI 1 signal indicator OFF There is no 5V HPD or HDMI signal detected on input FLASHING 5V HPD or HDMI signal is detected GREEN HDMI is active input and HDMI signal is detected 8 HDMI 1 IN Conn...

Page 9: ...tem working 6 SERVICE For firmware updated use 7 TCP IP Connect to a PC access to the Web GUI for system setting 8 HDBaset IN Connect to HDBaseT Transmitter with a Cat5e 6 7 cable 9 HDMI OUT Connect t...

Page 10: ...ed via Web GUI through TCP IP port The default IP address is 192 168 2 100 When the product has finished connection You can set the IP address to your PC laptop Internet Explorer and click Search to e...

Page 11: ...ual Effective Date 2020 01 06 Page 11 26 11 MAIN page Shows the status of the input signal Green The input port has connected an active signal Blue The input port has connected success but it has not...

Page 12: ...gle is the Mute setting to silence the amplifier and the audio extractor outputs Mute setting does not silence the audio on the HDMI output line System runs the system on off subroutine when switches...

Page 13: ...1 WP200 Kit User Manual Effective Date 2020 01 06 Page 13 26 13 CONTROL page Display System Sync When the toggle is in enable position the display on off subroutine will run the system subroutine on...

Page 14: ...d the system will change to active and fully controllable When the toggle is in disable position and the system is in standby status if a new signal is connected the system status won t change Relay S...

Page 15: ...out data when Display Off subroutine is called CR LF Appends a carriage return and line feed character to the end of the input strings as they are sent out Hex The commands can be input as hexadecimal...

Page 16: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 16 26 16 INPUT OUTPUT page Switch Mode Sets how the switcher plate will change between input signals...

Page 17: ...set to priority mode 1 is the highest priority and 3 is the lowest No Activity Timeout Sets the amount of time it will take for the unit to turn itself off when there is not detected input signal Audi...

Page 18: ...Kit User Manual Effective Date 2020 01 06 Page 18 26 18 EDID The name of the current EDID EDID Update Upload a bin file to change what EDID is stored in the device s internal memory that is used when...

Page 19: ...1 06 Page 19 26 19 The network settings of the device s internal system Room Label This is the user assigned label that appears at the top of the web interface The user and the admin password settings...

Page 20: ...6 20 the firmware of the control panel and the receiver box not the two gang transmitter To update the firmware of the two gang switcher use the USB port on the plate Note The default Username and Pas...

Page 21: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 21 26 21 When you set it over and you can click Login button to enter Web GUI function page The page likes below...

Page 22: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 22 26 22...

Page 23: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 23 26 23 7 System ON OFF Subroutine...

Page 24: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 24 26 24 8 Display ON OFF Subroutine...

Page 25: ...25 26 25 9 System Reset To perform a system reset hold the source button SOURCE button for 20 seconds until the HDCP light flashes three times When the system is reset user settings will return to th...

Page 26: ...File No RD I 20 012 Version 1 1 WP200 Kit User Manual Effective Date 2020 01 06 Page 26 26 26 10 Application Example...

Reviews: