INFLOOR 24535 Operating Instructions Manual Download Page 5

5

Step2, Mount appropriate pressing jaws on to pressing tool

A, You need to open the pressing tool handles and then take off two screws (Part No.1,M6

×

25), see

following picture.

B, Position the two opposite jaws in the pressing tool head, make sure the two jaws are evenly well

positioned and the specification number on the two jaws are on the same side, then fix the jaws with

the screws (Part No.1,M6 

 x 

  25).

Note:please don't over tighten the jaws, little looseness is allowed

C, Please pay attention to the jaw positioning, make sure the center of pressing hole formed by these

two opposite jaws is by the jaws openning direction rather than the handles opening direction.

D,

Trial-Pressing-Force

evaluation

Try to close the pressing tool without fitting and lengthened handles mounted, the appropriate

Trial-

Summary of Contents for 24535

Page 1: ...for 24535 and 24538 July 2008 Infloor Sales Service SW Adjustable Manual Pressing Tool Operating Instructions...

Page 2: ...jaws P 4 Step 2 Mount appropriate pressing jaws on to pressing tool P 5 Step 3 Adjustment for pressing tool P 6 4 Cautions and parameters for pressing tool adjustment P 7 5 Special operations at corne...

Page 3: ...pressing jaws used on the pressing tool 24535 are smaller than the jaws on pressing 1 Structure of Infloor Sales Service adjustable manual pressint tools Below is the pressing tool picture illustrate...

Page 4: ...lettered sides of the two opposite jaws are positioned on the same side The jaws engraved with specification number alone stand for U profile jaws for pressing F5 fittings 3 Preparation before use St...

Page 5: ...ation number on the two jaws are on the same side then fix the jaws with the screws Part No 1 M6 x 25 Note please don t over tighten the jaws little looseness is allowed C Please pay attention to the...

Page 6: ...ressing Force is too small you should turn the adjusting screw Part No 14 clockwise for about 1 4 round If the Trial Pressing Force is too big then you should should turn the adjusting screw counter c...

Page 7: ...before Closed pressing tool can be openned freely without using any force Pressing effect is bad 2 In case of new tools due to the burrs in tool production Operation Force change after 60 times of pre...

Page 8: ...e pressing tool then take off the pin Part No 6 fixed with the butterfly shape screw C Now you can adjust the angle from pressing tool head to pressing tool handles to make sure the jaws are rightly p...

Page 9: ...gthened handles then open the jaws and move the pressing jaws away from the pressed fitting without opening the handles or lengthened handles G Mount back the pin and the butterfly shape screw onto th...

Page 10: ...tool wears and final rejection Over a long time use the pressing tool components parts might wear out badly the Trial Pressing Force may not be able to reach about 33LBS or pressing jaws may not be a...

Page 11: ...se it should be kept in either of the following ways Open the pressing tool with jaws mounted in the pressing tool head keep well the threads on the lenthened handles Take off the jaws close the press...

Page 12: ...and anti corrosion agent should be sprayed onto the threads periodically E In use or tool adjustment the screws or pins taken off from the pressing tool should be well preserved We wish we have been o...