background image

C Series Handheld Thermal Camera 

·

User Manual 

                                                                                                                                          

 

3.

 

Select  the  image  mode  you  need  on  the  secondary  toolbar  and  press  the 

confirm button to switch into the selected image mode. 

4.8 Color Palette 

You  can  change  the  color  palette  to  distinguish  temperature  difference  on  the 

thermal  camera.  A  appropriate  color  palette  can  help  you  analyze  images  more 

easily. 

1.

 

In  the  thermal  imaging  interface,  press  the  center  button  to  display  the  main 

toolbar 

2.

 

Select the “Color Palette”

 icon on the toolbar

and press the center button 

to bring up the secondary toolbar 

3.

 

You  can  select  a  new  palette  and  press  the  center  button  to  switch  into  the 

selected palette. 

4.9 Shutter Correction

 

4.9.1 Shutter Correction Introduction 

Shutter correction is used to compensate for the non-uniformity of the detector 

pixels  or  the  non-uniformity  caused  by  other  optical  interference.  When  the 

picture effect is poor, you can perform shutter correction, which is common in 

situations where the ambient temperature changes rapidly. 

4.9.2 Shutter Correction Operation 

In  the  imaging  interface,  click  the  return  button  to  perform  a  non-uniformity 

correction.  During  shutter  correction,  the  screen  will  freeze  for  a  short  time, 

which is normal. 

 

 

 

 

Summary of Contents for Tianshu C Series

Page 1: ...Tianshu C Series Handheld Thermal Camera User Manual V1 0 1 IRay Technology CO Ltd www iraytek com...

Page 2: ...stall other equipment on the terminal product without the consent of IRay Technology IRay Technology authorizes the end user to use the product within the scope of authorization of the terminal equipm...

Page 3: ...ing Instructions 5 4 1 Power On Off 5 4 2 Saving Images 5 4 3 View Delete Pictures 5 4 4 Center Point Temperature Measurement 5 4 5 Cold Hot Spot Tracing 6 4 6 User defined Spot Measurement 6 4 7 Imag...

Page 4: ...it 11 5 3 High Low Temperature Alarm 11 5 4 Photo taking Settings 12 5 4 1 Automatically Save Photos 12 5 4 2 Timed Photo 12 5 5 Temperature Measurement Gear 12 5 6 System Settings 12 6 Structural Dra...

Page 5: ...Start Guide Please follow the below steps to get started 1 Charging Use 5V 1A or 5V 2A power adapter and USB cable to charge the device The device can be charged by connecting to PC with the USB cable...

Page 6: ...C Series Handheld Thermal Camera User Manual 2 3 Camera Introduction 3 1 Camera Components 1 Digital Camera 2 Infrared Lens 3 LED 4 Trigger 3 2 Buttons...

Page 7: ...select 4 Power Button Long press to power on off 5 Back Button Press to cancel operation or back to previous menu 6 LED Button Long press to turn on off the LED light 3 3 Connector Memory Card 1 USB...

Page 8: ...as selecting color palette 3 Temperature measurement point it is divided into center spot high temperature low temperature spot tracing and closing measurement spot user defined measurement spot 4 Ce...

Page 9: ...ttings auto save option 4 3 View Delete Pictures When you take and save a picture it will be stored in SD card you can view the saved image at any time as follows 1 Click the View Memory button to ent...

Page 10: ...t the measurement icon on the toolbar and press the center button to bring up the secondary toolbar 3 Select High Temperature or Low Temperature icon on the secondary menu and press the confirm button...

Page 11: ...age Infrared images only Fusion Fusion of infrared image and visual image in a certain scale In the main interface you can use the left and right navigation keys to adjust the fusion ratio of infrared...

Page 12: ...is the approximate distance from the thermal camera to the target In picture in picture thermal fusion digital camera mode please make sure that the thermal image displayed on the screen is aligned w...

Page 13: ...center button to bring up the secondary toolbar 3 You can select a new palette and press the center button to switch into the selected palette 4 9 Shutter Correction 4 9 1 Shutter Correction Introduc...

Page 14: ...percentage of energy reflected For example human skin emissivity is 0 98 and printed circuit board emissivity is 0 91 For more emissivity information you can refer to the quick start guide in the pack...

Page 15: ...it and Kelvin 5 3 High Low Temperature Alarm The camera supports the high and low temperature alarm function The user can set the high and low temperature alarm threshold The alarm function can be tur...

Page 16: ...Gear The temperature measurement range of the equipment is 20 550 In order to ensure the imaging effect and temperature measurement range the temperature measurement range is divided into 20 150 and 1...

Page 17: ...C Series Handheld Thermal Camera User Manual 13 6 Structural Drawing...

Page 18: ...scrub your equipment 5 Do not connect the attached connecting cable wrongly to avoid damaging the equipment 6 Please pay attention to prevent static electricity 7 Please do not disassemble the equipme...

Page 19: ...ermal Camera User Manual 15 9 Company Information IRay Technology Co Ltd Website www iraytek com Phone 86 0535 3410623 FAX 86 0535 3410610 E mail sales iraytek com Address 11th Guiyang Street YEDA Yan...

Reviews: