background image

   

                               

                                                                                                                                                                                                                                                                             

V1.0.1                                                                                        - 2 - 

Yantai  IRay  Technology  Co.,  Ltd. 

11th  Guiyang  Street,  YEDA 

Yantai 264006, P. R. China

 

 

2.

 

Product Specification 

Table 1 Product specification 

Model 

ITS300 

Thermal Imaging

 

Detector type 

VOx Uncooled Thermal FPA 

Resolution 

384×288 

Responsive spectrum 

8

14μm 

Lens

 

Focal length 

7.8mm 

Focus 

Auto/manual focus 

FOV 

47°×35.6° 

IFOV 

2.1mrad 

Visual Imaging

 

Resolution 

1920×1080 

Focal length 

4.7

141mm 

HFOV 

60.5°

2.3° 

Temperature Measurement

 

Measurement range 

0

60℃ 

Accuracy

1

 

   

±0.3℃@target temperature of 33℃

42℃, @ ambient temperature of 

16℃

32℃ (with blackbody) 

Measurement distance   

2

10m 

Connector

 

Power supply 

12VDC 

Network port 

2 100/1000Base-TX RJ-45 ports 

USB 

2 USB 2.0 ports 

Com port 

1 RS232, 1 RS485 

Alarm output 

GPIO

5 channels switching signal, 4 channels relay signal NC/NO 

Audio input 

1 LINE-IN 3.5mm port 

Audio output 

1 LINE-OUT 3.5mm port 

Video output 

HDMI   

 

Summary of Contents for ITSII 300

Page 1: ...ITS 300 AI Thermal Imaging Temperature Screening System Quick User Guide V1 0 1 Yantai IRay Technology Co Ltd...

Page 2: ...is used as a guide The photos graphics diagrams and illustrations provided in the manual are only used to explain which may be different from the specific product Please refer to the real object We t...

Page 3: ...d Connecting Camera 5 3 3 Blackbody Specification and Installation 7 3 4 Site Layout Solution 8 3 5 Site Installation and Layout Considerations 9 3 6 Parameter Setting Guidance 10 4 Software User Guid...

Page 4: ...g System developed for the epidemic situation The system combines high precision thermal temperature measurement and accurate face recognition technology which can quickly detect pedestrians of abnorm...

Page 5: ...2 1mrad Visual Imaging Resolution 1920 1080 Focal length 4 7 141mm HFOV 60 5 2 3 Temperature Measurement Measurement range 0 60 Accuracy 1 0 3 target temperature of 33 42 ambient temperature of 16 32...

Page 6: ...nalysis 1TB historical data storage retrieve in face mask alarm time Body temperature correction Intelligent human body temperature correction Flux 200 People minute Remote access Support web remote a...

Page 7: ...ry List Before installation please make sure that the equipment in the package is intact and all parts are available Optional package Prepared by users Displayer resolution 1920 1080 HDMI cable Tools...

Page 8: ...p of the product for fixing the camera to the adapter or bracket Figure 3 1 Structure of Camera Take the thermal camera mounted on a tripod as an example as follows Remove the tripod head counterclock...

Page 9: ...amera height according to the deployment scenario 1 7m 2m is appropriate Figure3 3 Camera Installation Connect the DC 12V power cable and network cable to the DC in port and RJ45 port of camera Figure...

Page 10: ...ment temperature 0 40 Temperature range Ambient temperature 5 50 Temperature resolution 0 1 Accuracy 0 2 35 Emissivity 0 97 0 02 Settling time 5min Temperature stability 0 1 0 3 h Effective radiant su...

Page 11: ...height and distance of infrared measurement thermal imaging camera and external reference blackbody are determined according to the specific application scene and specific model but the following pri...

Page 12: ...area of the camera market and shall not be shielded by pedestrians Figure 9 Infrared Imaging on PC Environmental requirements The infrared temperature measuring camera is arranged in an environment w...

Page 13: ...om with a constant temperature from a hot cold outdoor environment at this time a long enough channel needs to be reserved to allow the subject s body surface temperature to gradually stabilize before...

Page 14: ...etwork cardd1 192 168 1 124 Network card2 192 168 1 125 4 2 System Login There are two ways to login ITS II system one is login local server via GUI and another is login Web server via Explorer Figure...

Page 15: ...ccess Server or else it will warning login error 5 Troubles Shooting Troubles Shooting Fault description Possible Causes Method of exclusion Boot failure Power connector is loose Check whether the pow...

Page 16: ...ent light etc or it may damage the lens or detector Equipment used indoors should not be installed exposed to rain or very wet areas Do not place the equipment in an environment with corrosive gas whi...

Page 17: ...not squeeze the lens surface wipe liquid also can not dip in too much make sure the cloth is wet but wipe liquid can not be extruded If still not clean replace the cloth and repeat operation 6 3 Safe...

Page 18: ...V1 0 1 15 Yantai IRay Technology Co Ltd 11th Guiyang Street YEDA Yantai 264006 P R China Fax 86 0535 3410610 Email sales IRaytek com Address 11th Guiyang Street YEDA Yantai Shandong Province...

Reviews: