Infinova V5812IR-A8 Series Instruction Manual Download Page 6

Summary of Contents for V5812IR-A8 Series

Page 1: ...INSTRUCTION MANUAL V5812IR A8 Series High Resolution IR Minidome Camera ...

Page 2: ......

Page 3: ...peration is subject to the following two conditions This device will not cause harmful interference This device must accept any interference received including interference that may cause undesired operations The V5812IR A8 Series High Resolution IR minidome cameras have been tested and found to comply with the limits for a Class A digital device pursuant to the FCC rules With these rules and regu...

Page 4: ...commended by manufacturer Position power source and related wires to assure to be kept away from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation Indicate that the un insulated components within the product may carry a voltage harmful to humans Indicate operations that shou...

Page 5: ...el 2 1 4 Specifications 3 1 5 Notice 5 Chapter II Menu Settings 6 2 1 Image 6 2 2 Advanced 7 2 2 1 Zone Masking 7 2 2 2 Motion Detection 8 2 3 Day Night 8 2 4 Language 8 2 5 Load Default 8 2 6 Soft Version 8 2 7 Save Exit 8 2 8 Exit 9 Appendix I Cable Diameter Calculation and Lightning Surge Protection 10 ...

Page 6: ......

Page 7: ...or rendering ability and digital noise reduction function This camera also has infrared night vision function so it can still surveille the area even if there is no light As a result 24 hours continuous surveillance can be achieved This camera supports OSD menu display function It s friendly and intuitive user interface make it easy to operate This camera supports privacy mask which up to 8 masks ...

Page 8: ...olor reproduction Supports image enhancement Supports digital zoom Motion detection up to 4 areas Privacy mask up to 8 programmable masks Internal synchronization 3 axis adjustment Power Supply twelve volts of direct current 12VDC 1 3 Product Model This manual is for the following models V5812IR A8065SP High Resolution IR minidome camera 1 3 inch progressive scan CMOS sensor 800TV lines OSD PAL 2 ...

Page 9: ...Distance 30m Lens Fixed aperture F1 4 f 2 8 12mm Camera Angle Adjustment X Panning 0 360 Y Tilting 0 75 3 0 deviation Z Rotating 0 344 Digital Shutter Auto 1 50000s 1 25s Gamma Correction 0 45 White Balance AWB GW AWB CCT AWB PRO AWB TEMPORAL AWB AI Noise Reduction 3D Auto Manual 0 15 adjustable Image Enhancement Sharpness Contrast Saturation Rotating Mirror Reverse Digital Zoom Support 0 5 adjust...

Page 10: ...Power Consumption 2W Operating Temperature 14 F 122 F 10 C 50 C Storage Temperature 4 F 140 F 20 C 60 C Operating Humidity 0 90 RH non condensing Unit Dimensions H Ф 3 48 4 69 88 5mm 119mm Maximum Unfailure Working Time 20000 hours When infrared light failure is less than 30 ...

Page 11: ... the dust 3 When utilizing power supply please refer to our specifications 4 Camera should be firmly installed so that the damage of people or other objects for its precariousness and fall can be avoided 5 Do not put the camera near or above the radiator or heating resistor 6 Please be careful and avoid intense impact when using the camera 7 Please refer to the following dimension figure when inst...

Page 12: ...TINGS Main menu settings are as follows MAINMENU IMAGE ADVANCED DAY NIGHT EXTERNAL LANGUAGE ENGLISH LOAD DEFAULT SOFT VERSION V2 00 00 SAVE EXIT EXIT 2 1 Image 3D DNR IRIS EXPOSURE CONTROL WB IMAGE ENHANCE ZOOM IN 0 RETURN ...

Page 13: ...7 2 2 Advanced ZONE MASKING MOTION DETECTION MIRROR OFF FLIP OFF RETURN 2 2 1 Zone Masking COLOR MOSAIC AREA NO 1 AREA NO 2 AREA NO 3 AREA NO 4 AREA NO 5 AREA NO 6 AREA NO 7 AREA NO 8 RETURN ...

Page 14: ...TIVITY HIGH AREA NO 1 AREA NO 2 AREA NO 3 AREA NO 4 RETURN 2 3 Day Night DAY NIGHT EXTERNAL COLOR B W AUTO 2 4 Language LANGUAGE ENGLISH 中文 2 5 Load Default LOAD DEFAULT 2 6 Soft Version SOFT VERSION V2 00 00 2 7 Save Exit SAVE EXIT ...

Page 15: ...9 2 8 Exit EXIT ...

Page 16: ...meter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 61...

Page 17: ...e Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to...

Page 18: ......

Page 19: ......