![Infinova V2414 Installation & Operation Instructions Download Page 9](http://html.mh-extra.com/html/infinova/v2414/v2414_installation-and-operation-instructions_2056934009.webp)
3
2.4 Manchester Connection
There is one Manchester input port on the V2414 real panel. V2414
series Up-the-coax Code Converters convert the Manchester codes
from Infinova series video matrix switchers (V2011, V2015) to 16
Up-the-coax control signal outputs. Please refer to figure 2-2, which
demonstrates the connection between V2414 and V2011 matrix
switcher.
B
Connect a black code wire from the B terminal of the control
code source to the B terminal of V2414 series Up-the-coax Code
Converters.
W
Connect a white code wire from the W terminal of the control
code source to the W terminal of V2414 series Up-the-coax Code
Converters.
S
Connect one end of the shield cable to the S terminal of the
control code source. Connect the opposite end of the shield cable to
the S terminal of V2414 series Up-the-coax Code Converters.
Note:
Use 18 AWG, shielded, 2-wire cable, Belden 8760 or
equivalent for code line connections.
IN
OUT
DATALINE
MANCHESTER
RS485
B S W
R+ GND R-
SW1
SW2
VIDEO OUTPUT
VIDEO INPUT
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
V2414
DOME
DOME
10
11
12
13
14
15
16
10
11
12
13
14
15
16
MONITORS
RS232 PORTS
ALARMS
RELAYS
1 2 3 4 5 6 7 8
9
2
4
6
8
10
12 14
16
18
20 22
24
26
28
30
32
1
3
5
7
9
11 13
15
17
19
21
23
25
27 29
31
1
2
3
4
5
6
8
7
NONCCM
CAMERAS
NONCCM
B W S B W S B W S B W S
MANCHESTER CODE
1011121314 15 16
RS485 PORT
T+ T- GND
ETHERNET
1
2
3
4
V2011
Figure 2-2. Manchester code input