A
B
1
2
A
B
1
2
B-1switch positions allows the grinder to pulse
on for 30 seconds, o
ff
2 minutes on for 10
seconds and o
ff
2 minutes. This continues for
20 minutes. This provides adequate dry salt
aerosol in a booth or pod in the size range of
4’ x 4’ x 6’
A-2 (left switch up, right switch down) position
allows the grinder to pulse on for 60 seconds,
o
ff
2 minutes, on 30 seconds, o
ff
2 minutes and
continue this pattern for 20 minutes. This
provides adequate dry salt aerosol in a booth or
pod in the size range of 4’ x 4’ x 6’