tallation for indoor unit
Dimension drawing of indoor unit installation
Space to the wall
20cmabove
Space to the ceiling
15cmabove
�
-
- - - - - - - - -
-_,¡
230-260cm
Space to the floor
Mounting plate
1. The wall for installation of the indoor unit shall
be hard and firm, so as to prevent vibration.
2. Use the "+" type screw to fasten the peg board,
horizontally mount the peg board on the wall, and
ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation,
to confirm whether it is solid.
Wall-through Hole
1. Make a hole with an electric hammer or a
water drill at the predetermined position on
the wall for piping, which shall slant outwardly
by 5
º
-10
º
.
2. To protect the piping and the cables from
being damaged running through the wall,
and from the rodents that may inhabit in
the hollow wall, a pipe protecting ring shall
be installed and sealed with putty.
Note: Usually, the wall hole is Cl>60mm~Cl>80mm.
Avoid pre-buried power wire and hard wall
when making the hole.
- 18 -
www.infiniton.es
©@
Space to the wall
<=)2ocmabove