![Infinite AERINOS ADS-260 User Manual Download Page 18](http://html1.mh-extra.com/html/infinite/aerinos-ads-260/aerinos-ads-260_user-manual_2055512018.webp)
ADS-260 User Guide
18
7. Command Summary
7.1 Configuration Commands
Cmd
Description
Syntax
Comments
0160 Clear Event Log
cmd
0183 Set Factory Defaults
cmd,cmd
0205 Reset Unit Operation
cmd,cmd
0301 Set Device ID
cmd,id,p
id: unit ID, p: password
0790 Show Status Messages
cmd
0791 Hide Status Messages
cmd
1150 Enable Counter
cmd,n
n: counter
1154 Set Counter Scale Factor
cmd,n,f
n: counter, f: factor
1158 Set Counter Auto Clear
cmd,n,c
n: counter, c: auto clear
(0: no, 1: yes)
1160 Clear Counter Configuration
cmd,n
n: counter
1180 Clear Counter
cmd,n
n: counter
1181 Preset Counter
cmd,n,v
n: counter, v: value
1200 Set AI Configuration
cmd,n,ssl,ssh,sl,sh
ssl/ssh: sensor scale l/h,
sl/sh: User scale l/h
1210 Clear AI Configuration
cmd,n
n: AI
1230
Set SDI-12 Channel
Configuration
cmd,n,a,m,i
n: SDI AI, a: sensor address, m:
parameter set, i: parameter index
1238
Clear SDI-12 Channel
Configuration
cmd,n
n: SDI AI
1239
Clear All SDI-12 Channel
Configuration
cmd
1240
Set Modbus Trigger
Command
cmd,a,r,v
a: address, r: reg, v: value
1241
Set Modbus Channel
Configuration
cmd,n,a,c,sr,nr
n: Modbus AI, a: address, c:
command, sr: start reg, nr: number
of regs
1248
Clear Modbus Channel
Configuration
cmd,n
n: Modbus AI
1249
Clear All Modbus Channels
Configuration
cmd
1250 Set Massa AI Configuration
cmd,n,a,u,o
n: Massa AI, a: address, u: unit
(0:in, 1:cm), o: offset
1259 Clear Massa AI Configuration
cmd,n
n: Massa AI
1291 Set AI Power Up Delay
cmd,d
d: delay (sec)
1310 Set Send Period
cmd,p
p: period (minutes)
1600 Set Unit RTC Time
cmd,d,m,y,h,n,s
d: day, m: month, y: year, h: hour,
n: minutes, s: seconds