28.4.1.1.10 TCPWM_GRP_CNT_LINE_SEL
Description:
Counter line selection register
Address:
0x40380028
Offset:
0x28
Retention:
Retained
IsDeepSleep:
No
Comment:
Default:
0x32
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
None [7:7]
COMPL_OUT_SEL [6:4]
None [3:3]
OUT_SEL [2:0]
Bits
15
14
13
12
11
10
9
8
Name
None [15:8]
Bits
23
22
21
20
19
18
17
16
Name
None [23:16]
Bits
31
30
29
28
27
26
25
24
Name
None [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:2
OUT_SEL
RW
RW
2
Selects the source for the output signal 'line_out'.
Default setting is the PWM signal 'line'. Other settings
are useful for Stepper Motor Control.
This field has a function in PWM and PWM_PR modes
only.
Note: The output signal of this selection can be further
modified by the stop / kill logic and line_out polarity
setting (CTRL.QUAD_ENCODING_MODE[0]).
L
0
fixed '0'
H
1
fixed '1'
PWM
2
PWM signal 'line'
PWM_INV
3
inverted PWM signal 'line'
Z
4
The output 'line_out' is not driven by the TCPWM.
Instead the port default level configuration applies, e.g.
'Z' (high impedance).
Note: This is realized by driving the output
'line_out_en' to 0.
Reserved5
5
N/A
Reserved6
6
N/A
Reserved7
7
N/A
4:6
COMPL_OUT_SEL
RW
RW
3
Selects the source for the output signal
'line_compl_out'. Default setting is the inverted PWM
signal 'line'. Other settings are useful for Stepper Motor
Control.
This field has a function in PWM and PWM_PR modes
only.
Note: The output signal of this selection can be further
modified by the stop / kill logic and line_compl_out
polarity setting (CTRL.QUAD_ENCODING_MODE[1]).
L
0
fixed '0'
H
1
fixed '1'