2.2
Operating conditions
To avoid electrical damage of the demoboard, the values in
must be maintained.
Table 1
Limit values for operation
Parameter
Symbol
Values
Unit
Note or condition
Min.
Typ.
Max.
Board supply voltage
V
IN
0
–
42
V
–
Output voltage
V
Q
-0.3
–
7
V
Output current
I
Q
0
–
200
mA
Limited by overcurrent protection
Enable
V
EN
0
–
42
V
Watchdog inhibit
V
WINH
-0.3
–
7
V
Watchdog output
V
WO
-0.3
–
7
V
Watchdog input
V
WI
-0.3
–
7
V
Reset output
V
RO
-0.3
–
7
V
Ground voltage
V
GND
0
–
0
V
–
1)
T
A
= 25°C.
2)
Symbols refer to the connectors of the demoboard.
3)
Absolute maximum rating.
OPTIREG
™
linear voltage regulator TLS820F3ELVxx demoboard
Z8F68163446
2 Demoboard
User manual
6
Rev. 1.0
2020-02-26