User Manual
701
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Core Module (incl. ADC2)
Measurement Unit Control Register 4
SAMPLE_TIME_int
11:8
rw
Sample time of ADC2
0
H
MICLK4
, 4 MI_CLK clock periods
1
H
MICLK6
, 6 MI_CLK clock periods
2
H
MICLK8
, 8 MI_CLK clock periods
3
H
MICLK10
, 10 MI_CLK clock periods
4
H
MICLK12
, 12 MI_CLK clock periods (default)
5
H
MICLK14
, 14 MI_CLK clock periods
6
H
MICLK16
, 16 MI_CLK clock periods
7
H
MICLK18
, 18 MI_CLK clock periods
8
H
MICLK20
, 20 MI_CLK clock periods
9
H
MICLK22
, 22 MI_CLK clock periods
A
H
n.u.
, not used
B
H
n.u.
, not used
C
H
n.u.
, not used
D
H
n.u.
, not used
E
H
n.u.
, not used
F
H
n.u.
, not used
MCM_RDY
7
r
Ready Signal for MCM
1)
after Power On or Reset
0
B
MCM Not Ready
, Measurement Core Module in
startup phase
1
B
MCM Ready
, Measurement Core Module start-up
phase finished
RES
6:5
r
Reserved
Always read as 0
RES
4:1
r
Reserved
Always read as 0
MCM_PD_N
0
rwpt
Power Down Signal for MCM
0
B
MCM Disabled
, Measurement Core Module
disabled
1
B
MCM Enabled
, Measurement Core Module
enabled
1) MCM = Measurement Core Module
Table 373 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
00000401
H
RESET_TYPE_4
ADC2_CTRL4
Offset
Reset Value
Measurement Unit Control Register 4
1C
H
see
Field
Bits
Type
Description