TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Speed Synchronous Serial Interface SSC1/SSC2
21.5.2
Configuration Register
The operating mode of the serial channel SSC is controlled by the control register CON. This register contains
control bits for mode and error check selection, and status flags for error identification. Depending on bit EN,
either control functions or status flags and master/slave control are enabled.
Control Register
Field
Bits
Type
Description
RES
31:4
r
Reserved
Always read as 0; should be written with 0.
MIS_1
3
rw
Master Mode Input Select Bit 1 (Master Mode only)
0
B
Default
, Inputs selected according to MIS_0.
1
B
Do not use
, Connects to unused pins.
CIS
2
rw
Clock Input Select (Slave Mode only)
0
B
SSCx_S_SCK
, (x = 1 or 2, dependant form current SSC),
see
1
B
SSC12_S_SCK
, for both SSCs. See
SIS
1
rw
Slave Mode Input Select (Slave Mode only)
0
B
SSCx_S_MTSR
, (x = 1 or 2, dependant form current SSC),
see
1
B
SSC12_S_MTSR
, for both SSCs. See
MIS_0
0
rw
Master Mode Input Select Bit 0 (Master Mode only)
0
B
SSCx_M_MRST
, (x = 1 or 2, dependant form current SSC),
see
1
B
SSC12_M_MRST
, for both SSCs. See
.
Table 352 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
SSC_CON
Offset
Reset Value
Control Register
04
H
see
31
16
r
RES
15
4
r
RES
33
rw
MIS_
1
22
rw
CIS
11
rw
SIS
00
rw
MIS_
0