SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
76
Revision 1.0, 2011-12-15
2.15.7
Execution Information
2.15.8
Code Example
Figure 10
Code example for usage of StartXtalOsc()
Table 73
StartXtalOsc: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
1)
1) Values are obtained by extrapolation, not by characterization
t
30
–
1323
1440
µs
DIVIC is 0; delay is 30
t
40
–
1750
1901
µs
DIVIC is 0; delay is 40
t
delta
–
52,7
56,1
µs
DIVIC is 0; delta delay is 1
Charge
Consumption
Q
30
–
1,22
2,15
µC
DIVIC is 0; delay is 30
Q
40
–
1,6
2,83
µC
DIVIC is 0; delay is 40
Q
delta
–
0,05
0,09
µC
DIVIC is 0; delta delay is 1
// Library function prototypes
#include "SP37_ROMLibrary.h"
#include "Reg_SP37.h"
void main()
{
// Return value of start xtal oscillator is stored in StatusByte
unsigned char StatusByte;
// Input parameters for start xtal oscillator
unsigned char Delay = 33;
// Start xtal oscillator function call
StatusByte = StartXtalOsc(Delay);
}