Infineon REF-XDPL8219-U40W Getting Started Download Page 7

  

User Manual 

V 1.0 

 

 

2020-08-12

 

 

Getting started with the XDPL8219 reference board using .dp Vision 
software 

Getting started 

There are two options available to configure the IC based on the parameter values in .dp Vision:  

1) Non-permanent for testing  
2) Permanent for regular operation 

1)

 

Test configuration 

This function will download the parameter values from .dp Vision into the XDPL8219 RAM memory space, and it 

will then be followed by an automatic IC start-up for application testing with the new configuration. As long as 
the board is activated, the V

CC

 is supplied. 

Parameter configuration with this option is not permanent, because the loaded RAM content gets lost once the 

IC supply voltage is turned off or the IC restarts due to certain protections. For detailed information, please 
refer to the “dpvision User manual” in the “Documents” folder. 

Table 2

 shows the procedures for using the test configuration function in .dp Vision to load the new parameter 

values in the RAM and test the application with the new configuration. 

Table 2

 

Test configuration procedures  

Step 

Instruction 

Open configuration file (see example i

Figure 7

)

Ensure EN

UART,REPORTING

 parameter is disabled and change the desired parameter value. 

 

Note: If the EN

UART,REPORTING

 parameter is enabled, the success of the test configuration cannot be 

guaranteed, because .dp Vision will show an error due to being unable to get the status from 
XDPL8219 with UART reporting, after the automatic IC start-up with the new configuration in RAM.

 

Ensure that the primary supply voltage (AC input) to the board is not active and the hardware 

connection for configuration is OK based on 

Figure 2

 an

Figure 3

. 

Press   to supply power and establish a connection to the target XDPL8219. After this, XDPL8219 

will be in configuration mode and the device status   should change to  . 

5 (optional)  Ensure that the LED output is connected to a load, and switch on AC input (e.g. 230 V AC). 

After this, the board will not start because XDPL8219 is still in configuration mode. 

Press 

 to test the configuration with target XDPL8219. After this, the IC will automatically start 

normal operation with the new configuration and the window below will pop up:   

 

Note: If the parameter configuration is equivalent to the pre-existing parameters, the XDPL8219 

will not download them to RAM. 

Press “Close” on the pop-up window.  

To test another configuration, repeat these steps.  

New configuration is successfully downloaded to 
RAM and the application has started 

Summary of Contents for REF-XDPL8219-U40W

Page 1: ...e to operation of the XDPL8219 reference board for all power classes of LED lighting applications and how to use the dp Vision software to program the operating parameters of the XDPL8219 digital cont...

Page 2: ...2 Interface for programming the XDPL8219 digital controller USB cable To connect the dp Interface Gen2 with a PC Please download and install all the software tools Click on the links below Graphical u...

Page 3: ...the recent REF XDPL8219 U40W engineering report Incorrect use of the reference board could be dangerous and even life threatening 2 1 Hardware connection Connect the dp Interface Gen2 to a notebook PC...

Page 4: ...Interface Gen2 connection Figure 3 Connection between the dp Interface Gen2 and the XDPL8219 reference board Note Please ensure that the connector of the programming cable is plugged in correctly The...

Page 5: ...Vision Load the XDPL8219 parameters configuration file csv in the folder HOME Infineon Technologies AG dp vision Parameters as shown in Figure 6 Please select the corresponding file e g for a 40 W boa...

Page 6: ...Getting started Figure 7 Parameters file loaded in dp Vision Note The message bar shown in Figure 7 provides detailed information For further information please refer to the dpvision User manual Figur...

Page 7: ...UART REPORTING parameter is disabled and change the desired parameter value Note If the ENUART REPORTING parameter is enabled the success of the test configuration cannot be guaranteed because dp Visi...

Page 8: ...n 1 Load configuration file see example in Figure 7 2 Modify the parameter value needed then press File Save or File Save as to save the configuration file Otherwise proceed to step 3 3 optional Disco...

Page 9: ...V 1 0 2020 08 12 Getting started with the XDPL8219 reference board using dp Vision software Getting started Revision history Document version Date of release Description of changes V 1 0 12 08 2020 F...

Page 10: ...ended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product for the intended application and the completeness of the pro...

Reviews: