User guide
21 of 32
V. 1.0
2020-11-03
EVAL-M1-101TF user guide
iMOTION™ Modular Application Design Kit
System and functional description
Figure 21
Three input thresholds configuration for VSP analog input control mode
For analog Vsp control input mode, the motor speed can be calculated by measuring the frequency of PGOUT
signal output of control IC IMC101T-F048. And the pulse generation number per revolution of the motor can be
configured in MCEWizard as shown in Figure 22.
Figure 22
PG pulse per revolution configuration
Motor speed can be calculated as shown below.