Watchdog Timer
User’s Manual
16-21
V2.0, 2007-07
WDT, V2.0
16.4.7.3 WDT Period During Power-Saving Modes
Care needs to be taken when programming the WDT reload value before going to Idle
or Sleep Mode. As described on
, the state of bit 15 of the Watchdog counter
is used to wake-up from these modes. Thus, the reload value should be chosen such
that it is less then 7FFE
H
(bit 15 = 0); otherwise an immediate wake-up could occur. Only
half of the maximum periods shown in
can be used for the wake-up period.