PCP Control and Status Register, PCP_CS
This register can be Endinit-protected via bit EIE.
PCP_CS
PCP Control/Status Register
(10
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ESR
CWT
CWE
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PPS
PPE
CS
EIE RCB
0
RS RST EN
rw
rw
rw
rw
rw
r
rh
rwh
rw
Field
Bits
Type Description
EN
0
rw
PCP Enable
0
B
PCP is disabled for operation (default)
1
B
PCP is enabled for operation
Note: This bit does not enable/disable clocks for
power saving. It stops the PCP from accepting
new service requests.
RST
1
rwh
PCP Reset Request
0
B
No PCP software reset operation is requested
1
B
A PCP software reset is requested. Halt any
operating channel. Reset all control registers to
default values. Reset PCP state to default value.
RST is always read as 0, but is written with 1 in order
to initiate a reset. See also
.
RS
2
rh
PCP Run/Stop Status Flag
0
B
PCP is stopped or idle (default)
1
B
PCP is currently running
0
3
r
Reserved