![Infineon Technologies TC1796 User Manual Download Page 1214](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371214.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Synchronous Serial Interface (SSC)
User’s Manual
20-57
V2.0, 2007-07
SSC, V2.1
Pad Driver Mode Registers
The Port 2 and Port 6 Pad Driver Mode Registers contain bit fields that determine the
output driver strength, and the slew rate of SSC output lines.
P2_PDR
Port 2 Pad Driver Mode Register
(40
H
)
Reset Value: 0000 0000
H
31
22
20
18
16
0
0
PD
SLS1
0
PD
SLS0
0
PD1
0
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PDSLS0
[18:16] rw
Pad Driver Mode for P2.[3:2]/SLSO[3:2]
1)
1) Coding of bit field see
. Shaded bits and bit fields are “don’t care” for SSC I/O port control.
PDSLS1
[22:20] rw
Pad Driver Mode for P2.[7:4]/SLSO[7:4]
P6_PDR
Port 6 Pad Driver Mode Register
(40
H
)
Reset Value: 0000 0000
HH
31
22
20
18
16
0
0
PD
CANCD
0
PD
CANAB
0
PD
SSC1
0
0
0
r
rw
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PDSSC1
[22:20] rw
Pad Driver Mode for P6.4/MTSR1, P6.5/MRST1,
and P6.6/SCLK1
1)
1) Coding of bit field see