MHD Configuration Register (MHDC)
The Communication Controller accepts modifications of the register in
“DEFAULT_CONFIG” or “CONFIG” state only.
MHDC
MHD Configuration Register
(0098
H
)
Reset Value: 0000 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
SLT
0
SFDL
r
rw
r
rw
Field Bits
Type Description
SFDL
[6:0]
rw
Static Frame Data Length
(gPayloadLengthStatic)
1)
Configures the cluster-wide payload length for all Frames sent in
the static segment in double byte. The payload length must be
identical in all nodes of a cluster. Valid values are 0 to 127 (0 to
7F
H
).
1) This bit can be updated in “DEFAULT_CONFIG” or “CONFIG” state only!
SLT
[28:16] rw
Start of Latest Transmit
(pLatestTx)
Configures the maximum minislot value allowed before inhibiting
Frame transmission in the dynamic segment of the cycle. There
is no transmission dynamic segment if SLT is reset to zero. Valid
values are 0 to 7981 (0 to 1F2D
H
) minislots.
0
[15:7],
[31:29]
r
Reserved
Returns 0 if read; should be written with 0.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...