Alignment Dowels (22)
Infiltrator CM-1060 Tank Assembly Instructions
Page 2
Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436
Seam Clips (64)
Lid Screw Kit
P1 Plumbing Kit
Components
CM-1060 Tank Pallet Handling
CM-1060 pallets hold either 5 or 10 tanks.
Overall Dimensions (for 10-tank pallet)
• Stacked tanks: 134”L x 62”W x 79”H (3.4 m L x 1.6 m L x 2.0 m H)
• Stacked tanks on pallet: 136”L x 67”W x 86”H (3.5 m L x 1.7 m L x 2.2 m H)
Weight: 3,600 lbs (1,633 kg)
A forklift that has the following minimum specifications is needed to safely handle and off
load the CM-1060 pallet: 5,000 lb (2,268 kg) capacity, 32” (0.81 m) load center, minimum 66”
(1.68 m) arm and minimum 12’ (3.66 m) pick height.
The tank halves must be safely removed from the pallet using the Infiltrator Lifting Strap
Assembly. The CM-1060 tank pallets should never be tipped over! The Infiltrator
Lifting Strap Assembly is sized to pick up a maximum of 4 tank halves at a time using
a forklift. The safety lock spring hooks are to be connected to the rope handles on the
end walls of each tank. Set the tank halves on a clean surface to prevent damage or the
introduction of dirt and debris into the mid-seam area where the gasket, gasket groove, and
molded-in dowels are located. Set the tank halves on a clean surface, pallet, across several
4”x4”s, or a tarp to prevent damage or introducing dirt and debris to the mid-seam area
where the gasket is located. Never set the tank half with the gasket on any surface with the
gasket facing downward.
Tank Assembly
1. Remove all plastic wrap and strapping from the CM-1060 tank and components shipping
pallet. If serial numbers need to be recorded, Infiltrator recommends recording them while
the tank halves are stacked on the pallet. The serial number is located at the mid-seam
on the outlet end.
2. Using the Infiltrator Lifting Strap Assembly, attach the four lifting strap hooks to
the CM-1060 rope handles, located two on either end of the tank bottom half.
Slowly lift the inverted tank bottom straight up and off of the tank top nested below.
WARNING: TThe Infiltrator Lifting Strap Assembly supplied with the starter kit
is sized to pick up a maximum of four Infiltrator tank halves at one time. Never lift
more than four tank halves at one time with the Infiltrator Lifting Strap Assembly.
The Infiltrator Lifting Strap Assembly is intended for use ONLY with Infiltrator tanks
in accordance with these instructions; any other use of the Infiltrator Lifting Strap
Assembly is prohibited. Infiltrator Water Technologies will not be liable for any
problems that arise from unauthorized use of the Infiltrator Lifting Strap Assembly.
Note: Never set the tank half with the mid-seam area facing downward without the use of
4”x4”s on a clean surface, pallet, or clean tarp to prevent damage or the introduction of
dirt and debris into the mid-seam area where the gasket, gasket groove, and molded-in
dowels are located.
3. Lift and set the tank bottom half down on 4”x4”s above a clean surface or pallet, to
prevent damage or the introduction of dirt and debris to the mid-seam area where the
gasket groove, and molded-in dowels are located.
2