Using the Contact Probe (if equipped)

The optional metal contact probe offers additional capabilities when used with 
Whisper. The contact probe can be a useful accessory in diagnosing machinery. 
For best results, always use the headphones when using the contact probe to 
enable the heterodyne feature.
To use the contact probe, twist the threaded end into Whisper’s plastic nose piece 
and turn Whisper On. Touch the end of the contact probe to bearing housings, 
solenoids, pistons, and other mechanical equipment to allow the frequencies to 
travel into Whisper's ultrasonic transducer. Adjust sensitivity as needed.   Properly 
functioning machinery sounds smooth and clear, while poorly functioning 
machinery may make irregular or grinding noises. Over time you will learn to 
recognize when machinery sounds to be in good working order or when it sounds 
worn and in need of maintenance. 

WARNING

Do not place the contact probe in running machinery, fan cages, 
drive belts, or other moving parts. Always use extreme caution 
when using the contact probe around machinery.

Whisper Transmitter Accessory (if equipped)

Whisper Transmitter is an accessory which can be used with the Whisper 
Ultrasonic Leak Detector to locate leaks in walk-in coolers/freezers, wall and 
ceiling joints, around doors, windows, body seals, rubber moldings, ducts, etc. 
Whisper Transmitter produces the frequency detected by Whisper. By placing 
Whisper Transmitter in a sealed area and scanning the exterior of the area. 
Whisper can detect any signal escaping the sealed area. A flaw in the seal can be 
quickly and accurately pinpointed.
1. Turn the transmitter power switch on. The POWER indicator will illuminate to 

indicate it is operating.

NOTE:

You will not be able to hear the tone generated by the transmitter.

2. Place Whisper Transmitter into the area to be tested. Seal area to be tested 

completely.

3. Set the “Sensitivity” control on Whisper to maximum.
4. Scan the exterior area for the suspect leaks. To pinpoint leaks, see 

"Locating 

Leaks" on page 7

.

NOTE:

When using Whisper Transmitter and headphones, Whisper will indicate 
ultrasonic disturbances through a variable-pitch tone

Summary of Contents for WHISPER

Page 1: ...O P E R A T I N G M A N U A L Whisper Ultrasonic Leak Detector ...

Page 2: ...ety requirements for electrical equipment for measurement control and laboratory use General requirements IEC 60825 1 2014 Safety of Laser Products Part 1 Equipment Classification and requirements Emissions CISPR 11 EN 55011 2009 Emission standard for industrial scientific A1 2010 and medical ISM radio RF equipment Class B Immunity EN 61326 1 2013 Edition 2 0 EMC Measurement Control Laboratory Equ...

Page 3: ...ardous and damaging to eyes Never aim a laser pointer anywhere at or near any person or animal Laser pointers are designed to point at inanimate objects only In some states and provinces it is illegal to aim a laser pointer at a law enforcement officer or any other person The purchaser user is responsible for ensuring that his or her use of the laser pointer conforms to any local laws Do not point...

Page 4: ...rough a 0 004 in 0 01 cm diameter orifice at 5 0 psig from a 12 in 30 5 cm distance Usage Indoor or Outdoor Operating Temperature Range 32 F to 122 F 0 C to 50 C may be operated for a limited time in lower temperature environments Storage Temperature Range 14 F to 140 F 10 C to 60 C Humidity 85 RH NC Max Altitude 6500 ft 2000 m Power Supply 2 D cell alkaline batteries Battery Life with laser off A...

Page 5: ...ating sources of ultrasonic disturbances created by gases liquids or solids Whisper has different ways of indicating these disturbances When used without headphones Whisper s indicators will illuminate and the unit will beep in response to sources of ultrasonic noise When headphones are plugged in Whisper s heterodyne feature is enabled bringing ultrasonic frequencies to a range audible to the hum...

Page 6: ... noise Drag your finger downward on the sensitivity touch pad to reduce sensitivity in response to an increase in environmental noise Many variables can affect the amount of ultrasound generated by the leakage of gas through an orifice Such factors include the pressure vacuum relative to the surrounding environment how smooth the edges of the orifice are the diameter of the orifice Whisper s dista...

Page 7: ... a slow X a vertical and horizontal type sweeping motion while keeping the nose piece or rubber extension probe pointed in the general direction of the suspected leak 4 If you are using Whisper without headphones it will beep when an ultrasonic disturbance is detected If you are using headphones Whisper will make a variety of different noises due to its heterodyne feature See Heterodyne Feature fo...

Page 8: ...pointer at any person or animal High Noise Environments In noisy environments it may be necessary to tune out unwanted signals from other areas in close proximity to where you are scanning for leaks Begin by pushing the rubber extension probe over the nose piece When the extension is attached Whisper s sensing angle is reduced increasing the directional capability and reducing the effects of the a...

Page 9: ... other moving parts Always use extreme caution when using the contact probe around machinery Whisper Transmitter Accessory if equipped Whisper Transmitter is an accessory which can be used with the Whisper Ultrasonic Leak Detector to locate leaks in walk in coolers freezers wall and ceiling joints around doors windows body seals rubber moldings ducts etc Whisper Transmitter produces the frequency ...

Page 10: ...as power cells In addition INFICON does not warrant any instrument that has been subjected to misuse negligence or accident or has been repaired or altered by anyone other than INFICON INFICON s liability is limited to instruments returned to INFICON transportation prepaid not later than thirty 30 days after the warranty period expires and which INFICON judges to have malfunctioned because of defe...

Page 11: ......

Page 12: ...TWO TECHNOLOGY PLACE EAST SYRACUSE NY 13057 9714 USA Phone 1 800 344 3304 Fax 315 437 3803 E Mail service tools inficon com www inficonservicetools com 2017 INFICON 074 504 P1D ...