C.  Shutting Down

Allow pressure and temperature in the SFI to reach ambi-
ent/atmospheric conditions slowly.

MAINTENANCE

CAUTION:

Never  perform  any  maintenance  until  the

SFI has been vented to the atmosphere, has equilibrated to
ambient temperature, and has been drained of all process
liquids/gases.

Fig. 3   SFI-6000 Assembly

A.  Disassembly

See Fig. 2 for the SFI assembly.  Loosen the gland nuts by
hand.    Replacement  "O"  ring  is  size  2-021,  material  is
viton.    Replacement  cushion  gasket  is  1/32"  compressed
non-asbestos material (see “Parts List” below for details).  
Cushion gasket can protect glass from contact with metal.
Omission of cushion gasket will cause gland nut to scratch
top surface of glass and will cause glass breakage which
may  result  in  severe  damage  to  life  and  property.
Replacement glass should be free of scratches or chips that
may  cause  local  stress  concentration  and  lower  the
strength  of  the  glass  in  bending.    The  glass  is  available
through  INFERNO.    Do  not  substitute  glass  from  other
sources.  Original glass is tempered borosilicate (Pyrex).
Substitute glasses from other sources may not necessarily
be “high strength in  tempered condiotion.  For high pres-
sure operation the Inferno SFI must carry tempered glass
which is three times stronger than regular annealed glass.

B.  Reassembly

Inspect  "O"  ring  grooves  to  make  sure  that  there  are  no
nicks or imperfections that could cause leakage.  Blow off
all sanding dust or other debris from the body and gland
nuts and wipe all mating surfaces clean before re-assem-
bling.  Take special care to see that no remains of old cush-
ion gasket are left sticking to the glass or the end cap.

See Fig. 2 for the SFI assembly.  First insert "O" ring into
the groove on one side of the body.  Then place the glass
carefully over top of the "O" ring.  Install the cushion gas-
ket on top of the glass.  Lubricate the threads of the gland
nut.    Finally  hand-tight  the  gland  nut.    Hand-tight  is  all
that  is  required.  The  gland  nut  will  not  loosen  when  the
body is under internal hydraulic pressure, in fact the nut
will become very stiff and hard to turn.  Under no circum-
stance use wrench to tighten the gland nut.  Glass is sub-
ject  to  breakage  when  wrench-tightened  and  capable  of
causing severe damage to life and property.

Hydrotest to 1.5 times working pressure.  Or gas test sub-
merged under water to check for bubbles indicating leak-
age.

CAUTION: 

Gas testing must be done with great precau-

tion  because  large  amount  of  stored  energy  is  present  in
the SFI when pressurized with gas. A gas pressure check
should be done by specially trained personnel only.

C. Parts List- High Pressure 6000# SFI 

11376:  Hi Pressure Body v3, SA 479 T-316 CF stainless
steel. 

11377: Hi Pressure Gland nut v3, SA 479 T-316 CF
stainless steel.                                 

3261:  Cushion  gasket,  non-asbestos,  NBR  binder
(K-4401), 1/32" thick.

10821: Glass, clear, borosilicate glass tempered, 3/4"
thick x 1-1/4" diameter.

4063: Nozzle, 1/8" ID tubing, T-316 stainless steel. 

3255: "O" ring,Viton 90 durometer, Parker size 2-021.

Note: v3 parts shown above will not interchange with
earlier versions

Gland Nut

Body

"O" ring

Name Plate

Glass

Cushion
Gasket

Nozzle- press-in