Assembly 

Adhesive

Peel off  one protective

layer on the doublesided

adhesive sheets and stick them 

to the marked places on the 

controller.

If the device is installed on  

glass, cover it with 

a cover foil

Peel off  the second protective 

layer on the doublesided 

adhesive sheets and place the

control in the prepared place.

Adhesive

Place the mounting jig on the 

KU box and screw it on

In the installation box or on the wall

Snap on the controller.

Mount the snap bar on the 

controller into the installation 

box or on the wall

Summary of Contents for RFGB-240/B

Page 1: ...WIRELESS SWITCH SOCKET LUXURY VERSION EN Combination of iNELS wall mounted wireless controller and switch socket It is used to control el appliances lights fans etc...

Page 2: ...Glass touch controller 4 buttons WHITE SHARP Switching socket plug French EAN 8595188183437 Glass touch controller 4 buttons WHITE SHARP Switching socket plug Schuko EAN 8595188183338 Glass touch con...

Page 3: ...gluing with doublesided tape or just laying on the table RFGB 40 B glass touch controller SHARP black 4 buttons RFGB 40 W glass touch controller SHARP white 4 buttons RFGB 240 B glass touch controlle...

Page 4: ...lled on glass cover it with a cover foil Peel off the second protective layer on the doublesided adhesive sheets and place the control in the prepared place Adhesive Place the mounting jig on the KU b...

Page 5: ...ture Working Position Mounting Protection Pollution degree Dimension Weight Related standards 2x 3 V battery CR 2032 about 2 years depending on the frequency of use Red LED 4 RFIO2 868 5 MHz one way a...

Page 6: ...Notes...

Page 7: ...n button impulse relay and time function of delayed ON or OFF with time setting of 2 s 60 min The switched socket may be controlled by up to 32 channels 1 channel represents 1 button on the controller...

Page 8: ...EN 60730 EN 63044 EN 300 220 EN 301 489 Supply voltage Apparent power Dissipated power Supply voltage tolerance Output Number of contacts Rated current Switching power Peak current Switching voltage...

Page 9: ...iNELS RF Control and iNELS RF Control2 The detector can be assigned an iNELS RF Control2 RFIO2 communication protocol Radiofrequency signal penetration through various construction materials brick wa...

Page 10: ...are de energized While mounting and servicing observe safety regulations norms directives and professional and export regulations for working with electrical devices Do not touch parts of the device t...