Technical parameters /

 

More detailed information can be found in the iNELS RF Control Installation Manual:

https://www.elkoep.com/catalogs-and-brochures

ELKO EP, sro hereby declares that the type of radio equipment RFGB-20, RFGB-40,

RFGB-220, RFGB-240 is in accordance with Directives 2014/53 / EU, 2011/65 / EU,

2015/863 / EU and 2014 / 35 / EU. The full text of the EU Declaration of Conformity is

available on the following websites:

www.elkoep.com/glass-touch-controllers-white-sharp-rfgb-20w

www.elkoep.com/glass-touch-controller---2-buttons-black-sharp-rfgb-20b

www.elkoep.com/glass-touch-controller---4-buttons-white-sharp-rfgb-40w

www.elkoep.com/glass-touch-controller-4-buttons-black-sharp-rfgb-40b

www.elkoep.com/glass-touch-controller---2-buttons-white-round--rfgb-220w

www.elkoep.com/glass-touch-controller---2-buttons-black-round-rfgb-220b

www.elkoep.com/glass-touch-controller---4-buttons-white-round-rfgb-240w

www.elkoep.com/glass-touch-controller---4-buttons-black-round-rfgb-240b

When handling a device unboxed it is important to avoid contact with 
liquids. Never place the device on the conductive pads or objects, avoid 
unnecessary contact with the components of the device.

Safe handling /

 

Attention:
When you instal iNELS RF Control system, you have to keep 
minimal distance 1 cm between each units. Between the 
individual commands must be an interval of at least 1s.

Instruction manual is designated for mounting and also for user of the device. It is always a 
part of its packing. Installation and connection can be carried out only by a person with ad-
equate professional qualifi cation upon understanding this instruction manual and functions 
of the device, and while observing all valid regulations. Trouble-free function of the device 
also depends on transportation, storing and handling. In case you notice any sign of damage, 
deformation, malfunction or missing part, do not install this device and return it to its seller. 
It is necessary to treat this product and its parts as electronic waste after its lifetime is termi-
nated. Before starting installation, make sure that all wires, connected parts or terminals are 
de-energized. While mounting and servicing observe safety regulations, norms, directives and 
professional, and export regulations for working with electrical devices. Do not touch parts of 
the device that are energized - life threat. Due to transmissivity of RF signal, observe correct 
location of RF components in a building where the installation is taking place. RF Control is 
designated only for mounting in interiors. The must not be installed into metal switchboards 
and into plastic switchboards with metal door - transmissivity of RF signal is then impossible. 
RF Control is not recommended for pulleys etc. - radiofrequency signal can be shielded by 
an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote 
control. 

Warning /

P

o

w

er

 

vo

l

ta

g

e

:

Battery

 l

i

f

e

:

T

ransmission

 

indication

:

N

umber

 

o

capacitive

 

buttons

:

Communication

 P

rotoca

l:

F

re

q

uence

:

S

i

g

na

transmission

 

method

:

R

an

g

e

:

O

ther

 

data

O

peratin

g T

emprature

:

W

orkin

g P

osition

:

M

ountin

g:

P

rotection

:

P

o

ll

ution

 

de

g

ree

:

Dimension

:

W

ei

g

ht

:

R

e

l

ated

 

standards

:

RFGB-20

RFGB-40

RFGB-220

RFGB-240

3 / 4

Especifi  caciones técnicas

T

ensi

ó

n

 

de

 

a

l

imentaci

ó

n

:

Vida

 

de

 

pi

l

as

:

I

ndicaci

ó

n

 

de

 

transmisi

ó

n

:

mero

 

de

 

botones

:

P

rotoco

l

o

 

de

 

comunicaci

ó

n

:

F

recuencia

:

M

odo

 

de

 

transmisi

ó

n

 

de

:

Al

cance

:

M

ás

 

in

f

ormaci

ó

n

T

emperatura

 

de

 f

uncionamiento

:

 

P

osici

ó

n

 

de

 f

uncionamiento

M

onta

j

e

:

P

rotecci

ó

n

:

G

rado

 

de

 

contaminaci

ó

n

:

Dimensiones

:

P

eso

:

N

ormas

 

cone

x

as

:

Advertencia:
En la instalación de iNELS RF Control debe haber una distancia 
mínima entre las diferentes unidades de un centímetro. Entre 
los diferentes ordenes debe pasar al menos 1s.

2

x 3 

V

 

battery

 

C

20

3

2

 / 

2

pi

l

a

 

C

20

3

2

about

 

2

 

years

 

dependin

on

 

the

 f

re

q

uency

 

o

use

 / 

apro

x

imadamente

 

2

 

a

ñ

os

 

dependiendo

 

de

 l

a

 f

recuencia

 

de

 

uso

R

ed

 LE

D

 / 

ro

j

o

 LE

D

                      

2

                                         4                                          

2

                                            4

RFIO

866

922

 MH

z

one-

w

ay

 

addressed

 

messa

g

e

 / 

mensa

j

e

 

diri

g

ida

 

unidirecciona

l

mente

in

 

the

 

open

 

up

 

to

 

200

 

m

 / 

de

 

hasta

 

200

 

mts

 (

a

aire

 l

ibre

)

-10

 

...

 +

50

 °

C

any

 / 

cua

lq

uiera

adhesive

scre

w / 

pe

g

ado

atorni

ll

ados

IP

20

2

    

9

4 x 

9

4 x 

8

 

mm

                                                        

100

 x 

100

 x 

8

 

mm

  

122

 g                                

122

 g                                 

122

 g                                   

122

 g

EN 

60669

, EN 3

00

 

220

, EN 3

01

 4

89

 RTTE 

Directive

,N

V

 N

o.

 4

26

/

2000

 

Co

ll

.

 (

Directive

 

1999

 / E

C

),

EN 

60669

, EN 3

00

 

220

, EN 3

01

 4

89

 

norma

 RTTE, N

V

č

.

4

26

/

2000

S

b

 (

norma

 

1999

/ES)

El manual de uso está dirigido para la instalación y el usuario del dispositivo. Manual siempre 
está incluido en embalaje. La instalación y conexión puede realizar sólo personal con adecuadas 
cualifi  caciones profesionales, de conformidad con todas las regulaciones aplicadas, y que está 
perfectamente familiarizado con estas instrucciones y funciones del dispositivo. Función del 
dispositivo también depende del transporte, almacenamiento y la manipulación. Si se observa 
cualquier signo de daño, deformación, mal funcionamiento o pieza que falta, no instale este producto 
y devolvelo al vendedor. Con el producto y sus componentes debe ser tratado después de su vida 
útil como con residuos electrónicos. Antes de iniciar la instalación, asegúrese de que todos los cables, 
partes o terminales conectados están sin la conexión a la red. En el montaje y el mantenimiento se 
deben observar las normas de seguridad, normas, directivas y reglamentos para trabajar con equipos 
eléctricos. No toque las partes del dispositivo que están conectadas en la red - puede producir peligro 
de vida. Debido a la transmisibilidad de la señal RF, observe la correcta ubicación de los componentes
RF en un edifi  cio donde la instalación se lleva a cabo. RF Control está diseñado para montaje en 
interiores, las unidades no están diseñados para la instalación en exteriores y espacios húmedos, no 
se pueden instalar en cuadros eléctricos de metal y en cuadros eléctricos plásticos con puerta de 
metal - lo que empeora transmisividad de la señal RF. RF Control no se recomienda para el control 
de dispositivos que ofrecen funciones vitales o para controlar dispositivos tales como bombas, el. 
calentadores sin termostato, ascensores, montacargas, etc. - Señal de radiofrecuencia puede estar 
bloqueado por una obstrucción, interferida, la batería del controlador puede estar ya sin energía, etc. 
y por lo tanto el control remoto puede ser incapacitado.

Advertencia

Al manipular con el dispositivo sin embalaje es importante evitar el contacto con líquidos. 
Nunca ponga el dispositivo sobre objetos conductores, no toque los componentes en el 
dispositivo de forma innecesaria.

Manipulación segura con el dispositivo

Reviews: