iNels Elko AirTM-100S Quick Start Manual Download Page 4

4 / 4

AirTM-100S

Warning

Technical parameters

* Values are calculated under ideal conditions and may vary depending on the type of sensor 

connected

** Not included in the package
*** Depending on network coverage

Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is 
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualifi cation upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free 
function of the device also depends on transportation, storing and handling. In case you 
notice any sign of damage, deformation, malfunction or missing part, do not install this 
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated.  Before starting installation, make sure that all 
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for 
working with electrical devices. Do not touch parts of the device that are energized – life 
threat.  To ensure the transmission of the radio signal, make sure that the devices in the 
building where the installation is installed are correctly located. Unless otherwise stated, 
the devices are not intended for installation in outdoor and damp areas, they must not 
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents 
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters 
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby 
disabling the remote control. 

1x 3.6V LS 14500 Li-SOCl

2

 AA

0.4 years

2.1 years

8.5 years

9.9 years

5 – 12 V DC (on terminal)

+10 %; -15%

0.2 mW

250 mW

With a message from the server 

using setting pins, 

SET button, programming cable

message to the server

only when the battery is powered by a message 

on the server

button SET

Tamper

IN1, IN2

LS (LED sensor)**

MS, WS (magnetic sensor)**

SO (Contact, open collector)

Sigfox

RCZ1 868 MHz

Approx. 50 km***

25 mW / 14 dBm

-30…+60°C  (Pay attention to the operating 

temperature of batteries)

-30…+70°C

any

glue / screws

IP65

terminals, wires 0.5 – 1 mm

2

terminals, wires 0.5 – 1 mm

2

M16 x 1.5 for cable ø max. 10 mm

182 x 62 x 34 mm

100 g (without battery)

Power supply

Battery power:

Battery life by frequency *:

1x 10 minutes

1x 60 minutes

1x 12 hours

1x 24 hours

External power supply: 

Supply voltage tolerance:

Standby consumption:

Transmitting power consumption:

Setting

Setting:

Alarm Detection:

Battery status view:

Control

Control:

Digital inputs

Inputs:

Supported sensors for energy 

measurements:

Communication

Protocol:

Transmitter frequency:

Range in open space:

Transmission power (max.):

Other parameters

 

Working temperature:

Storage temperature:

Operating position:

Mounting:

Protection degree:

Connecting External Power:

Connection of the sensor:

Cable gommet:

Dimension:

Weight:

Sigfi x Ready Certifi cation

Certifi cation ID for AirTM-100S Pulse Transmitter: 

P_0094_B301_01

The company ELKO EP, as the manufacturer, is entitled to make technical modifi cations to the product, in the technical specifi cation and product manual, without prior notifi cation.

Reviews: