Inelco Keepower XL-pro Manual Download Page 7





How do I charge and select different charging 
modes

The different charging modes are selected in the menu.

Normal charging

 is used on normal batteries (Wet, open type),  

maintenance-free, GEL, AGM and sealed battery with a gas limit 
at 14.0V or 14.4V in Bulk charging, and 14.4V or 14.8V in After-
charge. (battery type is selected for determining the gas limet).
In the display the current voltage on t he battery is showed 
together with the charging current

Boost mode

 is used when trying to repair deep discharged 

batteries, and is further described under "The intelligent charging 
curve". 
In the display the current voltage on the battery is showed 
together with the charging current

Supply Mode

 is used as a power supply when e.g. the car is 

in a showroom and the cars facilities is used without the motor 
running. In case of overload, a warning is giving in the display. If 
heavy overload, the charger switches off to protect it self.

A battery has to be connected for activation of "Supply mode"

Please note that spark protection is not active when in 
supply mode.

Selection button

Red clips to +

Black clips to -

2009-03-02 keepower XL-pro manual  GB TA.indd   8

05-03-2009   11:24:54

46

Summary of Contents for Keepower XL-pro

Page 1: ...not be covered up or exposed to direct sunlight T h eb a t t e r y ma n u f a c t u r e r s a d v i c e s h a v et ob ef o l l o w e dc a r e f u l l y The charger can only be used for rechargeable le...

Page 2: ...ash light button Mains cable Plus clip Red Minus clip black Display Navigation buttons Selection button Enter and power on off USB charging connection Battery temperature sensor 2009 03 02 keepower XL...

Page 3: ...navigation in the menu Arrow Up is used for moving the cursor up in the menu Arrow Down is used for moving the cursor down in the menu Arrow Back is used for going back to the previous menu Select bu...

Page 4: ...d by pressing the back button scrolling to the language to be used and select i n gt h el a n g u a g eb y p r e s s i n gt h e S e l e c t b u t t o n Activate language selection Scrolling to select...

Page 5: ...either in the vehicle or using the keepower Intelligent Battery Care charger If charging has taken place within the last 4 hours a higher reading will be the result Testing of the battery will always...

Page 6: ...mode can be used Otherwise softcharge is activated automatically when charging starts recommended Deep Discharged ing is needed Charging will start with Softcharge Intelligent Boostcharge can be sele...

Page 7: ...repair deep discharged batteries and is further described under The intelligent charging curve In the display the current voltage on the battery is showed together with the charging current Supply Mo...

Page 8: ...Menu tree Actual number of selections might vary due to customisation Example menu tree Battery not connected Battery connected 2009 03 02 keepower XL pro manual GB TA indd 9 05 03 2009 11 24 54 47...

Page 9: ...eriod Bulk charging Indication on screen T h e B u l k c h a r g i n g p h a s ei s t h ep h a s ew h e r et h eb a t t e r y u n d e r a constant current is charged up to app 85 of the full capacity...

Page 10: ...s ei s u s e dt ok i c k s t a r t t h eb a t t e r y i f i t h a s l o w p o w e r T h i s B o o s t i s ma d ea s a ni n t e l l i g e n t b o o s t i n g T h i s me a n s that the charger is boosti...

Page 11: ...e charger is overloaded in the supply mode The charger has lost the mains supply during charging The charger needs service because it have failed during the self testing No battery is connected The cl...

Page 12: ...ether with the appliance 1 2 Temperature sensor The keepower XL pro version has a temperature sensor in the battery clamps This sensor is used to adjust the charging parameter while charging the batte...

Reviews: