How do I charge and select different charging
modes
The different charging modes are selected in the menu.
Normal charging
is used on normal batteries (Wet, open type),
maintenance-free, GEL, AGM and sealed battery with a gas limit
at 14.0V or 14.4V in Bulk charging, and 14.4V or 14.8V in After-
charge. (battery type is selected for determining the gas limet).
In the display the current voltage on t he battery is showed
together with the charging current
Boost mode
is used when trying to repair deep discharged
batteries, and is further described under "The intelligent charging
curve".
In the display the current voltage on the battery is showed
together with the charging current
Supply Mode
is used as a power supply when e.g. the car is
in a showroom and the cars facilities is used without the motor
running. In case of overload, a warning is giving in the display. If
heavy overload, the charger switches off to protect it self.
A battery has to be connected for activation of "Supply mode"
Please note that spark protection is not active when in
supply mode.
Selection button
Red clips to +
Black clips to -